11.7.20 Directly displaying jobs in the map area when JP1/AJS3 - View is started from JP1/IM - View

When connecting to JP1/IM - View, you can start the Jobnet Monitor window by selecting a job on the Main Console screen of JP1/IM - View and clicking the Start Monitor button. You can display the highest jobnet, to which the selected job belongs, in the map area directly. You can display the jobnet to which the selected job belongs in the map area directly.

Specify from:
A JP1/AJS3 - View file
For details, see 11.1.1 Individual-user customization.

Specification
Use the following format:
jajsExecJobnetMonitorAllJobName={Yes|No} (return)
 
Specify Yes to display the specified job directly in the map area. Specify No not to display the specified job directly in the map area.
The default is No. If you omit this setting, No is assumed.
To display the jobnet to which the specified job belongs directly in the map area, you need to change the jobnet monitor start interface definition file in JP1/IM before specifying the above.
To change the file:
  1. Terminate JP1/IM - View started.
  2. Rename console-path#\conf\console\monitor\hitachi_jp1_ajs2_mon_en.conf, and create a backup file.
    The following gives an example:
    Before the change: hitachi_jp1_ajs2_mon_en.conf
    After the change: hitachi_jp1_ajs2_mon_en.conf.0671
  3. Copy JP1/AJS3 - View-installation-folder\conf\hitachi_jp1_ajs2_mon_en.conf.0700 to the following folder:
    console-path#\conf\console\monitor
  4. Change the name of the file copied in procedure step 3 as follows:
    Before the change: hitachi_jp1_ajs2_mon_en.conf.0700
    After the change: hitachi_jp1_ajs2_mon_en.conf
  5. Restart the JP1/IM - Console service.
#
The console path is the path to the JP1/IM - Manager installation folder. The default console path is as follows:
system-drive\Program Files\HITACHI\JP1Cons

Cautionary note
If you performed an upgrade installation or an overwrite installation for JP1/IM - Manager after you stored the jobnet monitor start interface definition file in the JP1/IM - Manager installation folder, store the file in the folder again.

Example
Display the specified job in the map area directly.
jajsExecJobnetMonitorAllJobName=Yes (return)