Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Automatic Job Management System 3 Troubleshooting


2.7.5 Troubleshooting problems related to jobnet connectors

This subsection describes how to troubleshoot problems related to jobnet connectors.

Organization of this subsection

(1) A Jobnet connector does not terminate

Use the jobnet monitor or another method to check the execution status of the connection destination jobnet. If the status of that jobnet is Ended normally, Ended abnormally, or Ended with warning, a failure might have occurred. If the status is different from the above, the jobnet connector is waiting for a jobnet to end at the connection destination (the normal status).

If you want to advance the execution without waiting for the jobnet to end at the connection destination, change the status of the jobnet connector to Ended normally. Note, however, that the status of the jobnet connector and the status of the connection destination jobnet no longer match.

When the connection destination jobnet ends, use the messages output to the integrated trace log, and to the Windows event log or to syslog, to eliminate the cause of the failure. Next, re-execute the connection destination jobnet. When you re-execute the connection destination jobnet, generations are connected between the jobnet containing the jobnet connector and the connection destination jobnet, resulting in normal operation of the jobnet connector. For details about connecting generations, see 2.2.4(2) Rules governing connections between jobnet connectors and connection-destination jobnets in the Job Management Partner 1/Automatic Job Management System 3 System Design (Work Tasks) Guide.

If you want to advance the execution of the jobnet connector without re-executing the connection destination jobnet, change the status of the jobnet connector to Ended normally. Note, however, that the status of the jobnet connector and the status of the jobnet on the connection destination will no longer match.

(2) A connection destination jobnet does not start after the scheduled start time is reached

Use the jobnet monitor or another method to check the execution status of the jobnet containing the jobnet connector. When the execution order control method is set to synchronous and the jobnet connector is waiting, the jobnet status is normal. If the jobnet connector is executing, a failure might have occurred.

When the execution order control method is set to synchronous and you want to start executing the connection destination jobnet without waiting for the jobnet connector to start, temporarily change the execution order control method to asynchronous.