2.3 Command property file (command_user.properties)
This is the definition file for setting the http port that is used for executing commands.
If you change the port number used for communications between JP1/AO and the Web browser, you must also change the http port used for executing commands to the same number.
Format
specification-key-name=setting
Installation folder
- For non-cluster systems:
-
JP1/AO-installation-folder\conf
- For cluster systems:
-
shared-folder-name\jp1ao\conf
Trigger for applying definitions
Updating the definition file
Description
One specification key and setting can be specified per line. Note the following points when coding the command property file.
-
Lines that begin with # are treated as comments.
-
Blank lines are ignored.
-
The encoding is ISO 8859-1.
-
The entries are case sensitive.
-
To specify a backslash (\) in a character string, two backslashes (\\) must be entered.
In this case, assume two backslashes as one byte to calculate the size.
-
If an invalid value is entered for a setting, it is set to its default value, and the KNAE02022-W message is output to the integrated trace log and public log.
-
If the same specification key is entered multiple times in a file, the last one that is specified will take effect.
Settings
Key name |
Settings |
Specifiable value |
Default value |
---|---|---|---|
command.http.port |
Specifies the http port used for executing commands. |
1-65535 |
23015 |
Example definitions
command.http.port = 23015
Related topics