Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Integrated Management - Manager Messages


KNAN26142-W

The amount of data that a remote event-log trap collected from the host exceeded the limit. The event-log entries output from the last collection time to this collection time will not be output as JP1 events. (host name: host name,previous collection time: Last collection time (yyyy/MM/dd hh:mm:ss), this collection time: This collection time (yyyy/MM/dd hh:mm:ss))

Because the amount of data collected from the monitored host exceeded the limit that can be collected, the event-log entries output from the previous collection time to this collection time will not be output as JP1 events. The next monitoring will collect the event-log entries output from this collection time by the monitored host.

S:

Continues the event log trap.

O:

On the monitored host, check the event log data output from the previous collection time to the present collection time. If the present collection time is earlier than the previous collection time, the date and time on the manager host is different from the date and time on the monitored host. In such a case, this message might also be output for the next monitoring. Synchronize the time on the manager host and monitored host.

If this message frequently appears for the same monitored host, consider taking the following corrective actions:

  • Make sure that the date and time on the manager host is the same as the date and time on the monitored host.

  • Make sure that an event log entry for a time later than the current time of the monitored host does not exist on the monitored host.

  • Specify a filter (-filter option of the jcfaleltstart command) as a startup option.

  • Shorten the monitoring interval.

  • Use an agent configuration for monitoring.