KAJV2301-W
A JP1 event (event ID = event-ID, serial number in the event database = serial-number-in-event-database) could not be correlated because the correlation event generation condition (correlation-event-generation-condition-name) has already correlated maximum-number pairs of JP1 events.
A single correlation condition can correlate multiple pairs of JP1 events up to the number of simultaneous correlations specified (CORRELATION_NUM; if not specified, 10).
Generation processing could not be performed on the received JP1 event because the generating condition displayed in the message is already correlating maximum-number pairs of JP1 events.
- S:
-
Continues processing.
- O:
-
Carefully review the generating conditions.
-
Determine whether an unnecessarily long time-out time was specified.
-
Determine whether the combination of event conditions is valid.
-