4.4.4 Application Monitoring (SSO) system-monitoring object
Item |
Description |
|
---|---|---|
Monitoring node type |
Application Monitoring (SSO) |
|
Purpose |
Monitoring of the application status monitored by JP1/Cm2/SSO version 8 or earlier |
|
Basic information |
Event-issuing host name |
Host name of a monitoring server where JP1/Cm2/SSO version 8 or earlier is installed Example: host01 |
Application name |
Name of an application monitored by JP1/Cm2/SSO version 8 or earlier Example:JP1/PFM |
|
Host name |
Host name of a server whose resources are to be collected and monitored by JP1/Cm2/SSO version 8 or earlier Example: host02 |
Status change condition |
Common condition#1 and individual condition |
|||
---|---|---|---|---|
Condition name |
Status |
Condition |
Values to be compared |
|
Application Alert event (SSO) |
Alert |
Application Alert event (SSO)#1 |
Event ID (B.ID) |
00003A80 |
SNMP Object ID (E.SNMP_OID) |
---.(109|112|115)#2 |
|||
Source name (E.SNMP_VARBIND3) |
Host name in the basic information |
|||
Event-issuing host name (E.SNMP_VARBIND2) |
Event-issuing host name in the basic information |
|||
Application name (E.SNMP_VARBIND1) |
Application name in the basic information |
|||
Application error event (SSO) |
Error |
Application Alert event (SSO)#1 |
Event ID (B.ID) |
00003A80 |
SNMP Object ID (E.SNMP_OID) |
---.(108|110|111|113|116|118)#2 |
|||
Source name (E.SNMP_VARBIND3) |
Host name in the basic information |
|||
Event-issuing host name (E.SNMP_VARBIND2) |
Event-issuing host name in the basic information |
|||
Application name (E.SNMP_VARBIND1) |
Application name in the basic information |
|||
Process monitoring failure warning event (SSO) |
Alert |
Process monitoring failure warning event (SSO)#1 |
Event ID (B.ID) |
00003A80 |
SNMP Object ID (E.SNMP_OID) |
---.304#2 |
|||
Host name of a monitored machine (E.SNMP_VARBIND1) |
Host name in the basic information |
|||
Event-issuing host name (E.SNMP_VARBIND4) |
Event-issuing host name in the basic information |
|||
Process monitoring failure error event (SSO) |
Error |
Process monitoring failure error event (SSO)#1 |
Event ID (B.ID) |
00003A80 |
SNMP Object ID (E.SNMP_OID) |
---.303#2 |
|||
Host name of a monitored machine (E.SNMP_VARBIND1) |
Host name in the basic information |
|||
Event-issuing host name (E.SNMP_VARBIND4) |
Event-issuing host name in the basic information |