4.4.1 Settings for monitoring system-monitoring objects for JP1/Cm2/SSO version 8 or earlier
This subsection provides necessary settings for monitoring system-monitoring objects for JP1/Cm2/SSO version 8 or earlier. The following items must be set:
-
Because JP1/Cm2/SSO version 8 or earlier does not issue JP1 events, you must use the JP1/Base function to convert SNMP traps (issued by JP1/Cm2/SSO for JP1/Cm2/NNM version 8 or earlier, or HP NNM version 7.5 or earlier) into JP1 events. During the conversion, you must use the SNMP trap conversion function of JP1/Base to set capturing of the variable binding of an SNMP trap.
-
To monitor application monitoring (SSO), you must edit the definition file (ssoapmon.def) for JP1/Cm2/SSO version 8 or earlier so that the source name of the variable binding for an SNMP trap is captured.