Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Integrated Management - Manager Administration Guide


9.3.2 Configuring JP1/IM - View

The following describes how to configure JP1/IM - View.

Organization of this subsection

(1) Enabling the setting that allow users to respond to and work with response-waiting events

In the Preferences window of JP1/IM - View, you can enable the setting that allows individual users to respond to and work with response-waiting events. After you enable this setting, users can:

To allow users to respond to and work with response-waiting events:

  1. Display the Preferences window.

    In the Event Console window, from the Options menu, choose User Preferences.

  2. In the Response-waiting event area, select the Enable check box.

  3. Click OK.

For details about the Preferences window, see 2.42.6 Preferences window in the manual Job Management Partner 1/Integrated Management - Manager GUI Reference.

(2) Configuring the event receiver filter

You can use an event receiver filter to limit which JP1 events each user can monitor. If you do not wish for a particular user to view response-waiting events, configure the event receiver filter to hide those events. By default, response-waiting events are displayed.

For details on how to create and modify an event receiver filter, see 4.2.2 Settings for event receiver filters in the Job Management Partner 1/Integrated Management - Manager Configuration Guide.

For details about the Detailed Settings for Event Receiver Filter window, see 2.42.8 Filter condition definition windows in the manual Job Management Partner 1/Integrated Management - Manager GUI Reference.