Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Base User's Guide


J.1 Settings for individual products that use JP1/SES events

Organization of this subsection

(1) Using HiRDB

(a) Using the event notification function

If the pd_jp1_event_level operand is set to 1, you must perform the following:

  • Delete the options v5-unused parameter in the event server settings file (conf). This parameter inhibits V5 compatibility.

  • Specify a TCP port for the service JP1AutoJob in the services file.

    For details on how to do this, see C.1 Port numbers for JP1/Base.

    Examples are shown below:

    JP1AutoJob  5001/tcp  # JP1/AutoJob Event Service

    Specify the same number (5001) for the port and the destination.

If the pd_jp1_event_level operand is set to 2, these settings are not necessary.

V5 compatibility might be discontinued in the future. If the environment permits it, we recommend setting the pd_jp1_event_level operand to be set to 2.

(2) Using the ajsevput command

Specify the settings as described above in (1)(a) Using the event notification function for the case when the pd_jp1_event_level operand is set to 1.

The ajsevput command might be discontinued in the future. We recommend migrating to an environment that uses the JP1/Base jevsend or jevsendd command.

(3) Using the ajsevget command

Specify the settings as described above in (1)(a) Using the event notification function for the case when the pd_jp1_event_level operand is set to 1.

The ajsevget command might be discontinued in the future. We recommend migrating to an environment utilizing a user program that uses the JP1/Base event acquisition function.