4.4.2 Setup procedure for restarting processes managed by the process management function

  1. Edit the extended startup process definition file (jp1bs_service_0700.conf).

    For details on the extended start process definition file, see Extended startup process definition file in 16. Definition Files.

  2. Enable the setting.

    To enable the automatic restart setting, restart JP1/Base or execute the reload command (jbs_spmd_reload).

  3. Disable Dr. Watson error notification (Windows Server 2003 or Windows XP only).

    If an error occurs and the Dr. Watson message box is displayed, the process cannot be restarted, so you need to disable the message display.

    From the Start menu, choose Run, and then execute drwtsn32. In the Dr. Watson dialog box, clear the Visual Notification check box.

    Because the settings for Dr. Watson are common to the whole system, the settings here are applied to the settings of all programs in the system.

    From the command prompt, execute the following command to enable the settings for Dr. Watson:

    drwtsn32 -i 

    This command installs Dr. Watson as the default application debugger.

  4. Disable Microsoft error reporting (Windows Server 2003 or Windows XP only).

    When an error occurs, a dialog box for reporting the error to Microsoft appears. This prevents the process from restarting. You must therefore disable such error reporting.

    1. In the Control Panel, double-click System.

    2. Select the Advanced tab, and then click Error Reporting.

    3. Select the Disable error reporting radio button, and make sure that the But notify me when critical errors occur check box is cleared.