Use the following formulas to determine the size of the memory required to execute the integrity check utility (pdconstck).
| Condition | Formula for the memory requirement (KB) |
||
|---|---|---|---|
| HiRDB/Single Server | 32-bit mode | 11,664 + |
|
| 64-bit mode | 22,696 + |
||
| HiRDB/Parallel Server | 32-bit mode | MGR | 7,577 + |
| DS | 5,772 + |
||
| 64-bit mode | MGR | 9,240 + |
|
| DS | 12,776 + |
||