HiRDB Datareplicator Version 8 Description, User's Guide and Operator's Guide

[Contents][Glossary][Index][Back][Next]

6.5.8 Notes on handling when sendcontrol=sendmst is specified

The following notes on the operating Datareplicator apply when sendcontrol=sendmst is specified in the extraction system definition.

Organization of this subsection
(1) Target Datareplicator connection/disconnection timing
(2) Suppression of transmission process reutilization

(1) Target Datareplicator connection/disconnection timing

When you specify sendcontrol=sendmst, communication with the target Datareplicator is established and broken at the specified transmission interval. However, if there is no update information to be sent when the transmission interval is reached, connection or disconnection processing does not occur. Therefore, when sendcontrol=sendmst is specified, the following operation is different from when sendcontrol=nodemst is specified:

(2) Suppression of transmission process reutilization

If an error occurs in a transmission process due to a memory shortage while transmission is underway, the source Datareplicator cancels transmission processing for the corresponding destination and suppresses reutilization of this transmission process. To reuse this transmission process, you must restart the source Datareplicator.