The following are the notes at the time of system operations:
- Service Coordinator creates and uses Reliable Messaging queue. If you operate this queue with commands of Reliable Messaging, the status of the HCSC server becomes invalid. Therefore, do not operate the queue.
- You cannot access the network drive from Service Coordinator. Do not specify a path on a network drive in arguments and various definitions of commands.
- In Windows, execute all HCSC server operations with users belonging to the "Administrators" group.
- In Windows, the active /passive status of the menu of HCSC-Manager Plug-in is not reflected immediately and a menu that cannot be executed might be activated in some cases. To set to an appropriate status, select a view different from the view that is currently in active status.
- In Windows, when you use HCSC-Manager, do not execute [Window]-[New Window] from the Eclipse menu.
- In Windows, it is recommended that you use HCSC-Manager Plug-in functionality other than login in the HCSC-Manager perspective.
- Warning message KDCCE0605-W is output during HCSC server operations, but you need not take any action.
- At the time of using HCSC server, you cannot use SSL/TLS communication using RSA BSAFE SSL-J.
- If the stub has been generated from WSDL of the old version, re-generate the stub based on WSDL of a new version.
- When you send and receive an XML message, characters within the message are converted to character references and entity references depending on the contents of the message and your system configuration. The notation system for character references and entity references are "& # x61" and "& lt". For details on character references and entity references, see the description related to character references and entity references in the XML 1.0 document.
- The timing for committing transactions of business processes has been changed in 09-00.For details, see "3.4 Business process transactions " in "Service Platform Overview".
- You cannot use parser switching function in the HCSC server. For the parser switching function, see "3.7 Parser switching functionality" in "Application Server XML Processor User Guide".
- The root application information is displayed in the message text of the KDEC00001-E and KDEC60002-E messages in the version 08-00 or later of this product.