KFCT73445-E
cannot output trace information to a trace-file.
- Description
- The trace information cannot be output to a file.
- The output of the trace file will be stopped. This message is displayed when the buffer for acquiring PRF trace is insufficient.
- Action
- Forcibly stop a running PRF daemon. After this, normally start the PRF daemon. To stop the PRF daemon forcibly, add the -Force option to the cprfstop command, and then execute the command.
- Also, in order to avoid this error, we recommend that you set the buffer size for acquiring PRF trace to a value greater than the default value (8192 kilobytes). For details on changing the buffer size, see the cprfstart command in the manual Cosminexus Application Server Reference - Commands.