uCosminexus Application Server, Messages
![[Contents]](FIGURE/CONTENT.GIF)
![[Back]](FIGURE/FRONT.GIF)
KFCT73004-W
failure to initialize for prf tracing service. ID:aa....aa reason code=bb....bb-cc....cc
- aa....aa: PRF daemon identifier
If the service identifier cannot be identified, **** is displayed.
bb....bb: Reason code
cc....cc: Internal system code
- Description
- An error occurred in the initialization of the PRF daemon service in the process.
- The PRF trace acquisition of the process in which the error occurred will be suspended. This initialization is a preparatory process to acquire the PRF trace in the process.
- Note that, this message may also be output during command execution.
- Action
- Based on the list of reason codes described in the following table, remove the cause of the error.
Table 19-14 List of failure reason codes displayed in KFCT73004-W
| Reason code |
Cause |
| 101 |
Memory is insufficient. |
| 106 |
The directory specified in the environment variable PRFSPOOL may not have been created correctly. |
| 115 |
The shared memory controlled by the PRF daemon cannot be accessed. If output with a command, confirm that the specified PRF daemon is running. |
| 1601 |
An error occurred in the system call. |
All Rights Reserved. Copyright (C) 2012, 2013, Hitachi, Ltd.