uCosminexus Application Server, Messages

[Contents][Back][Next]

KFCT71201-W

cannot open a new connection for inter-ctmd. maintenance code1 : aa....aa code2 : bb....bb

aa....aa: Maintenance code1
bb....bb: Maintenance code2
Description
An attempt to establish a connection between the CTM daemons has failed.
The processing continues, but a message cannot be sent.
Action
Confirm the following details, and then take action:
  • Are the specified values of the -CTMMaxCTM option, the CTMClientConnectCount option, and the -CTMServerConnectCount option invalid?
    Specify an appropriate value in the -CTMMaxCTM option, the -CTMClientConnectCount option, and the -CTMServerConnectCount option
  • Is the memory insufficient?
    Terminate the unnecessary processes or increase the memory.
  • Is the network interface abended?
    Change the network interface settings so that communication is possible.
  • Are the settings for the interlinking of multiple osagent (including between networks) invalid?
    Specify valid settings for the interlinking of multiple osagent (including between networks). For details, see the Borland(R) Enterprise Server VisiBroker(R) Developer's Guide.