uCosminexus Application Server, Messages

[Contents][Back][Next]

KFCT71052-W

convert an object reference to string/convert string to an object reference error for CORBA object. maintenance code : aa....aa

aa....aa: Maintenance code
Description
An attempt to convert a CORBA object to a string or to restore the object has failed.
The processing continues, but communication is not possible.
Action
Confirm the following details, and then take action:
  • Are the specified values of the -CTMMaxCTM option, the CTMClientConnectCount option, and the -CTMServerConnectCount option invalid?
    Specify an appropriate value in the -CTMMaxCTM option, the -CTMClientConnectCount option, and the -CTMServerConnectCount option
  • Is the memory insufficient?
    Terminate the unnecessary processes or increase the memory.
  • Is the network interface abended?
    Change the network interface settings so that communication is possible.
  • Is a process with an object (CTM daemon or CTM domain manager) abended?
    Restart the process as defined in CTM.
  • Is a process with an object been restarted on a different port?
    Specify the -CTMPort option for the process.