uCosminexus Application Server, Messages
![[Contents]](FIGURE/CONTENT.GIF)
![[Back]](FIGURE/FRONT.GIF)
KFCT70543-E
the error occurred while accessing domain manager information file.
- Description
- An error occurred while accessing the CTMSPOOL information file.
- The processing of the command and the daemon will be interrupted.
- Action
- Confirm the following details:
- An attempt to acquire the lock for the CTMSPOOL information file may have failed. Check whether a command is running for 10 or more seconds and whether a daemon is being started up for 10 or more seconds at the same time as the command or daemon that outputs this message.
- The CTMSPOOL information file may not exist. Check whether the CTM domain manager is not started even once after installation.
- Check whether a message was output before this message.
- Check the above details, and then take actions as follows:
- When a running command and a starting up daemon do not exist, restart the command or the daemon.
- Start the CTM domain manager. See the message that was output before this message, and then remove the cause of the error.
All Rights Reserved. Copyright (C) 2012, 2013, Hitachi, Ltd.