uCosminexus Application Server, Messages
![[Contents]](FIGURE/CONTENT.GIF)
![[Back]](FIGURE/FRONT.GIF)
KEOS29750-E (C/F)
An attempt to lock the virtual server group failed. (management unit name = aa....aa, virtual server group name = bb....bb, details = cc....cc)
- aa....aa: Management unit name
bb....bb: Virtual server group name
cc....cc: Details
- Description
- An attempt to lock the virtual server group failed. The possible causes are that the configuration of the load balancer is incorrect, or the logical status is Not Setup.
- The processing will be cancelled.
- Action
- Execute the vmiunit status command to check the logical status of the virtual server. Also, check the message details.
- Remove the cause of the error based on the details, and then re-execute the command.