KEOS28532-E (C/F)

The built and status for the logical server cannot be acquired.

Description
The setup and operation status of the logical server cannot be acquired.
The processing will be cancelled.
Action
Check whether the following file exists:
Cosminexus-installation-directory/manager/spool/logicalserver.xml.bak
Take the following action based on whether the logicalserver.xml.bak file exists:
If the logicalserver.xml.bak file exists
Rename the logicalserver.xml.bak file to logicalserver.xml, and then re-execute the command.
Note that even if unsetup is successful with this action, a stopped or undeleted logical server might exist and the rebuilding of the environment might fail. In such a case, stop the running logical server processes manually and then delete the real server.
If the logicalserver.xml.bak does not exist
Stop the running logical server processes manually, delete the real server, and then re-execute the command.