uCosminexus Application Server, Messages
![[Contents]](FIGURE/CONTENT.GIF)
![[Back]](FIGURE/FRONT.GIF)
KEOS20505-E (F)
Administration Agent on cc....cc(Host) could not be connected in aa....aa(bb....bb) processing.
- aa....aa: Logical server name
bb....bb: Logical server type
cc...cc: Host name
- Description
- A connection cannot be established with the Administration Agent.
- The start and stop process will be interrupted.
- Action
- Start and stop once again from the start/stop screen of the logical server. If the same phenomenon occurs even if started and stopped once again, check whether the Administration Agent is running in the operation host of the applicable logical server.
- Check the following details if the Administration Agent is running:
- Does the application server version of the Administration Agent match with the Management Server?
- If the application server editions of the Administration Agent and the Management Server are different, confirm that these editions can be connectable each other.
All Rights Reserved. Copyright (C) 2012, 2013, Hitachi, Ltd.