uCosminexus Application Server, Messages
![[Contents]](FIGURE/CONTENT.GIF)
![[Back]](FIGURE/FRONT.GIF)
KEOS10119-E (C/F)
Management Server could not be initialized normally.
- Description
- An attempt to set up the Management Server has failed.
- The command execution will be suspended.
- Action
- The possible causes are as follows: Take the necessary action depending on the cause.
- Management Server is already set up.
Continue the process.
- The specified server name is invalid.
Change the server name, and then re-execute the command.
- The specified server name is already in use.
Change the server name, and then re-execute the command.
- The prerequisite programs are not installed.
Confirm that the prerequisite programs of the product are installed, and then re-execute the command.
- Management Server is started. (In Windows)
Stop Management Server, and then re-execute Management Server.
- If you are unable to resolve the problem with the actions as mentioned above, see mngsvr.exe.1~16.log, mngsvr.exe.out, mngsvr.exe.err, mngsvrctl.exe.1~16.log in Windows, and to mngsvrctlstart.1~16.log and the message output on the console in UNIX, remove the cause of the error, and then re-execute the command.