KEOS10112-E (C/F)
Management Server service could not be started from command line.
- Description
- An attempt to start the Management Server Service from the command line has failed.
- The command execution will be suspended.
- Action
- The possible causes are as follows. Take the necessary action depending on the cause.
- Management Server Service is already running.
Continue the process or stop the service, and then restart the Management Server Service.
- Setup command is not executed.
Execute the setup.
- The contents of mserver.properties file are incorrect.
Check the contents of mserver.properties file.
- The prerequisite programs are not installed.
Confirm that the prerequisite programs of the product are installed, and then re-execute the command.
- The synchronous execution is timed out (when the command completion code is 3).
After a pause, use the mngsvrutil check command, and confirm that Management Service is operating.
- If you are unable to resolve the problem with the actions mentioned above, see mngsvr.exe.1~16.log, mngsvr.exe.out, mngsvr.exe.err, mngsvrctl.exe.1~16.log in Windows, and mngsvrctlstart.1~16.log and the message output on the console in UNIX, remove the cause of the error, and then re-execute the command.