The redirector cannot be used because the value specified for the worker.<worker-name>.post_data parameter in the worker definition file has already been defined for another worker. (worker.aa....aa.post_data = bb....bb, other worker = cc....cc)

aa....aa: Worker name of the worker, the value of which is duplicated
bb....bb: Value
cc....cc: Worker name
Description
The redirector cannot be used because the value obtained by adding 1 to the upper-limit value of the Content-Length header of the worker aa....aa specified in the worker definition file is same as the value specified in another worker cc....cc.
Action
Specify the appropriate value in the parameter worker.worker-name.post_data (the worker name is aa....aa) of the worker definition file, and then restart the Web server.