The performance trace is unavailable due to failure of initialization. (reason = aa....aa)
Table 7-4 List of failure reason codes displayed in KDJE39221-W
| Reason code | Cause | Action |
|---|---|---|
| -1 | Either the environment variable PRFSPOOL is not set, or the directory set in the environment variable PRFSPOOL does not exist. | Confirm that the environment variable PRFSPOOL is set. |
| -2 | An error occurred in the service start processing of the PRF demon present in the process. | The PRF demon might not be invoked. Confirm that the PRF demon is invoked. Also, check the PRFID of the definition file. |
| -3 | An error (such as system call error) occurred in the service start processing of the PRF demon present in the process. | See the log file present below setup-directory-of-environment-variable-PRFSPOOL\log\PRF-identifier (in Windows) or $PRFSPOOL/log/PRF-identifier (in UNIX), check the Cosminexus Performance Tracer message, and then take action based on the cause. |
| -4 | An attempt to load the library required for the service of PRF demon has failed. | Take action based on the following causes:
|