The web container server could not be connected. (server name = aa....aa)
- aa....aa: Server name
- Description
- The Web container server (aa....aa) cannot be connected.
- Either the Web container server is not started, or the webserver.shutdown.port value set in the user property file might be changed while starting the Web container server.
- Action
- Confirm that the Web container server aa....aa is started.
- If the Web container server is running, take the following actions depending on the status:
- If the webserver.shutdown.port value is changed, return to the settings during the startup of the Web container server, and then re-execute the cjstopweb command.
- If the webserver.shutdown.port value is not changed, forcibly end the processes of the Web container server with the help of the task manager (in Windows).
- Note that if the webserver.shutdown.port value is not specified, 8005 is set as the default value.