Appendix D.2 Monitoring processes for HP-UX

The following indicates the process names for HP-UX.

The number enclosed in parentheses indicates the number of processes that can be executed simultaneously. In the column containing two process names, the upper one is the parent process name, and the lower one is the child process name.

Organization of this subsection
(1) Relay system monitoring processes
(2) End workstation monitoring processes
(3) Client workstation monitoring processes

(1) Relay system monitoring processes

The following table shows the relay system monitoring processes.

Process name Function
rdscltsvc(9999) Receives startup requests from UDP.
rdstcpsvc(9999) Receives startup requests from TCP.
rdsrshmng(9999)
rdsactrsh(9999)
Manages the number of connections to the client.
Issues a startup request to the client.
rdsdaemon(9999) Monitors rdsocket.
rdssyscns(1) Manages system configuration information.
rdsregular(1) Manages the job execution date and time.
rdssnda(1)#1 Monitors execution results of jobs including distribution and collection, and reports the results to the upper-level server.
admmaster(1)#2
rdpcmsrvm(1)#2
Monitors processes for the distributor tools.
Controls processes for the distributor tools.

#1
  • The rdssnd command can start and stop this process.
  • If you set 0 in WatchTimeofStatus of the settings file, do not execute this monitoring process.

#2
Do not specify this process unless you use the distributor tools.

(2) End workstation monitoring processes

The following table shows the end workstation (END is specified for WorkstationType of the settings file) monitoring processes.

Process name Function
rdscltsvc(9999) Receives startup requests from UDP.
rdstcpsvc(9999) Receives startup requests from TCP.
rdsdaemon(9999) Monitors rdsocket.
rdssnde(9999) Monitors execution results of jobs including distribution and collection, and reports these results to the managing server.
rdsregular(9999) Manages the job execution date and time.

(3) Client workstation monitoring processes

The following table shows the client workstation (CLIENT is specified for WorkstationType of the settings file) monitoring processes.

Process name Function Notes related to the value of WatchTimeofOrders in the settings file
rdscltsvc(9999) Receives startup requests from UDP. If 0 is specified, this process is generated.
If MANUAL is specified, do not execute this monitoring process.
rdstcpsvc(9999) Receives startup requests from TCP. If 0 is specified, this process is generated.
If MANUAL is specified, do not execute this monitoring process.
rdsrfa(9999)# Connects to the relay system and checks for jobs addressed to the local system. If 0 or MANUAL is specified, do not execute this monitoring process.
rdsregular(9999) Manages the job execution date and time. If 0 or MANUAL is specified, this process is generated.

#
The rdsrf command can start and stop this process.