Job Management Partner 1/Integrated Management - Manager Configuration Guide
Lists of profiles that are to be managed by IM Configuration Management can be collected from the agents. The collected information is displayed in the tree area of the Display/Edit Profiles window.
The profile lists are placed in unregistered status at the time of any of the following operations:
- Initial startup of IM Configuration Management
- Collection of host information
- Reflection of system hierarchy
- Execution of the jcfimport command
To collect profile lists:
- In the IM Configuration Management window, click the IM Configuration tab.
The IM Configuration page is displayed.
- Use one of the following methods to display the Display/Edit Profiles window:
- From the menu bar, choose Display, and then Display Profiles.
- From the pop-up menu that is displayed by right-clicking, choose Display Profiles.
- From the tree area, choose a JP1 product name (JP1/Base), and then use one of the following methods to update a profile list:
The profile tree is rebuilt and the profile list is updated. If you have restarted the agent or the agent's JP1/Base, rebuild the profile tree before you edit or apply the profile.
- From the menu bar, choose Operation, and then Rebuild Profile Tree.
- From the pop-up menu that is displayed by right-clicking, choose Rebuild Profile Tree.
- From the menu bar in the IM Configuration Management window, choose Operation, and then Batch Collect Profiles.
The profile lists to be managed by IM Configuration Management are collected from the agents.
- Notes
- If profile tree rebuild processing fails, an error message is displayed, together with the profile tree that existed before the rebuild processing was executed. Although you can perform operations on the profiles that existed before the rebuild processing and on profiles whose information is still the same as at the agents, such operations may have adverse effects on future operations. It is better to eliminate the cause of the error and then re-execute the profile tree rebuild processing.
- Collection of profile lists fails if multiple event log traps are started using the same operation definition file or using operation definition files with the same name in different directories.
All Rights Reserved. Copyright (C) 2009, Hitachi, Ltd.