Job Management Partner 1/Performance Management - Remote Monitor for Platform Description, User's Guide and Reference
Overview
The Used Swap Mbytes alarm monitors the memory usage status.
Main settings
Table 4-18 Alarm property settings in PFM - Web Console (Used Swap Mbytes)
Alarm properties in PFM - Web Console Setting Item Details Main Information Product RM Platform Message Used swap is %CVS megabytes Enable alarm Selected Monitoring time range Always monitor Report alarm when the following damping condition is reached Selected Interval(s) 3 occurrence(s) during 2 Action -- Command -- SNMP Abnormal, Warning, Normal Conditional expression Record System Summary (PI) Field Used Swap Mbytes Abnormal condition Used Swap Mbytes >= 1024#1 Warning condition Used Swap Mbytes >= 1024#2
- Legend:
- --: The setting is always ignored.
- #1
- A guideline for the value to be set is about 90% of the value set for Total Swap Mbytes.
- #2
- Set the same value as for Total Mem Mbytes.
Alarm table
PFM RM Platform Template Alarms 09.00
Related reports
Reports/RM Platform/Troubleshooting/Real-Time/Pool Nonpaged Status
- Note
- 1024 is set as the value for this alarm for both abnormal and warning conditions. To use this alarm, change the values for abnormal and warning conditions as appropriate to the user's environment.
All Rights Reserved. Copyright (C) 2009, Hitachi, Ltd.