Job Management Partner 1/Performance Management - Remote Monitor for Platform Description, User's Guide and Reference
Overview
The Available Memory alarm monitors the unused size of the physical memory area (in megabytes).
The monitored value is the total size of zero memory, available memory, and standby memory (already cached) that can be allocated to processes or that can be used immediately by the system during collection. This is the most recent monitored value, not an average value.
Main settings
Table 4-3 Alarm property settings in PFM - Web Console (Available Memory)
Alarm properties in PFM - Web Console Setting Item Details Main Information Product RM Platform Message Available memory is below %CVS megabytes Enable alarm Selected Monitoring time range Always monitor Report alarm when the following damping condition is reached Selected Interval(s) 3 occurrence(s) during 2 Action -- Command -- SNMP Abnormal, Warning, Normal Conditional expression Record System Summary (PI) Field Free Mem Mbytes Abnormal condition Free Mem Mbytes < 3 Warning condition Free Mem Mbytes < 4
- Legend:
- --: The setting is always ignored.
Alarm table
PFM RM Platform Template Alarms 09.00
Related reports
Reports/RM Platform/Troubleshooting/Real-Time/Memory Used Status