22.8 KDEA10000 to KDEA11999
This section describes messages KDEA10000 to KDEA11999 and explains what actions to take in response to each message.
-
KDEA10001-W
The parameter is outside the valid range. The default value will be used. (parameter = aa....aa, value = bb....bb, default value = cc....cc)
aa....aa: Parameter name
bb....bb: Specified value of the parameter
cc....cc: Default value of the parameter
- Description
-
the specified value of the parameter is invalid. The default value will be used.
- Action
-
Check the specified value of the parameter and change it to the correct value.
-
KDEA10002-E
The parameter is outside the valid range or was not specified. (parameter = aa....aa, value = bb....bb)
aa....aa: Parameter name
bb....bb: Invalid specified value of the parameter (or null or NULL if no value was specified)
- Description
-
The parameter was not specified, or the specified value is invalid.
- Action
-
Check the specified value of the parameter, change it to the correct value, and then restart the EADS server.
-
KDEA10005-E
A received packet was invalid for the protocol. (local = aa....aa:bb....bb, remote = cc....cc:dd....dd)
aa....aa: Local IP address
bb....bb: Local port number
cc....cc: Remote IP address
dd....dd: Remote port number
- Description
-
A received packet was invalid for the protocol.
- Action
-
The possible causes are as follows:
-
A problem has occurred at the remote system with which communication was underway.
-
A network problem occurred.
Determine the cause of the error, and then eliminate it.
-
-
KDEA10006-W
A packet incompatible with the communications protocol was received. (local = aa....aa:bb....bb, remote = cc....cc:dd....dd)
aa....aa: Local IP address
bb....bb: Local port number
cc....cc: IP address of the connection source
dd....dd: Port number of the connection source
- Description
-
An incompatible packet was received.
- Action
-
The possible causes are as follows:
-
A problem has occurred at the remote system with which communication was underway.
-
The remote system is not compatible with the local system.
-
A network problem occurred.
Determine the cause of the error, and then eliminate it.
-
-
KDEA10007-E
Some parameter values conflict. (parameter1 = aa....aa, parameter2 = bb....bb)
aa....aa: Parameter 1 containing a conflicting value
bb....bb: Parameter 2 containing a conflicting value
- Description
-
The value of parameter 1 conflicts with the value of parameter 2.
There is a problem in the relationship between the parameters, such as in an inequality relationship.
- Action
-
Check the parameter values, correct them, and then restart the EADS server.