17.8.3 Notes about running user functions
-
User functions can be executed only on active EADS servers. If an EADS server's status is changed while a user function is running, any data operations performed thereafter by that user function will result in an error.
-
If the EADS server process is forcibly terminated by the eztool forcestop command or an OS function, the destroy method of the Function interface is not called.
-
The user is responsible for maintaining the consistency of user functions among the EADS servers. If an attempt is made to execute a user function when it is not located on a specific EADS server, an error is returned to the EADS client.
-
The EADS servers execute the user functions even if their implementation differs among the EADS servers.