Stream information was found that does not match any stream information of a conversion source defined in a mapping definition. Query group name = aa....aa, conversion source name = bb....bb
- aa....aa: Query group name. When a mapping definition is defined more than once within a single output adaptor definition, * is displayed.
bb....bb: Conversion source name. When a mapping definition is defined more than once within a single output adaptor definition, * is displayed.
- Description:
- The following are possible causes of the error.
- Stream information was found that did not match the stream information of a conversion source defined in a mapping definition. The stream information (query group name, stream name) of the mapping definition and reception CB definition did not match.
- A mapping definition is defined more than once within a single output adaptor definition.
- No format conversion definition is defined within an output adaptor definition.
- System processing:
- Suspends processing.
- Action to take:
- Check the following items.
- Are the tag and attribute settings of the adaptor structure definition file correct?
- Are editing CB definitions within an output adaptor definition defined in the order mapping definitions, format conversion definitions, with only one of each?
All Rights Reserved. Copyright (C) 2011, Hitachi, Ltd.