Job Management Partner 1/Integrated Management - Manager Messages

[Contents][Index][Back][Next]


2.1 Messages related to Central Console - View (KAVB0001 to KAVB2000)

KAVB0001-E


System error occurred.
Details:detailed-information

An unexpected error was detected during processing.

S:
Aborts processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0002-E


Specify the input-information.

A required item in the window is not entered.

S:
Waits for re-entry of information.

O:
Enter the missing item.

KAVB0003-E


Specify the input-information ranging from condition-1 to condition-2.

A value outside the specifiable range was entered in the input item in the window.

S:
Waits for re-entry of information.

O:
Enter the input item correctly.

KAVB0004-E


Failed to obtain the user profile.

The user profile could not be obtained.

S:
Aborts processing.

O:
Contact a system administrator.

KAVB0005-I


Updated the settings.

Updating of the items entered in the window has ended normally.

KAVB0007-E


Specify the input-information ranging from condition-1 to condition-2.
input-information:input-value

A value outside the specifiable range was entered in the input item in the window.

S:
Waits for re-entry of information.

O:
Enter the input item correctly.

KAVB0008-E


Failed to obtain the definition-file file.
Details:detailed-information

Due to the following reason(s), a view filter or event search log could not be obtained during startup processing.

  • A communication error occurred.
  • The definition file is corrupted.

S:
Continues startup processing using a filter for which no condition has been set.

O:
Restart JP1/IM - View.
If a KAVB1531-E message was output in the integrated trace log of the connected manager host, take the corrective action given for that message.

KAVB0009-E


Failed to obtain the definition-file file.
Details:detailed-information

A severe event filter, event acquisition filter, or user filter could not be obtained because a communication error occurred.

S:
Aborts processing.

O:
Retry the operation. If the same message is displayed, use the data collection tool to collect data, and then contact a system administrator.

KAVB0010-E


Failed to update the definition-file file.
Details:detailed-information

The definition file of the server could not be updated.

S:
Aborts processing.

O:
Retry the operation. If the same message is displayed, use the data collection tool to collect data, and then contact a system administrator.

KAVB0011-E


Add the input-information.

A required item has not been added.

S:
Waits for re-entry of information.

O:
Add the required input information, and then retry the operation.

KAVB0061-E


The product information could not be acquired because there was not enough memory.
Detailed information:function-name, return-value

An attempt to acquire product information failed due to insufficient resources.

S:
Suspends processing.

O:
Make sure that there are sufficient system resources.
Resolve insufficient resources, and then retry the operation.
If the problem persists, use the data collection tool to collect data, and then contact a system administrator.

KAVB0062-E


The product information could not be acquired because the environment is invalid.
Detailed information:function-name, return-value

An attempt to acquire the product information failed due to an invalid environment.

S:
Suspends processing.

O:
Determine whether a system error has occurred.
Uninstall and reinstall the program, and then retry the operation.
If the problem persists, use the data collection tool to collect data, and then contact a system administrator.

KAVB0063-E


A system error occurred during startup of product-name.

A system error occurred during startup of product-name.

S:
Suspends processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0101-E


Cannot connect to the connecting host.

Connection to the connecting host failed due to the following reason(s):

  • The entered connecting host name is incorrect.
  • The connecting host is not running.
  • An error occurred in communication with the connecting host.

If you use an integrated monitoring database, the IM database service is not in operating status.

S:
Aborts processing.

O:
Check the following items, and then retry the operation.
  • Is the entered connecting host name correct?
  • Is the connecting host running?
  • Is there a problem communicating with the connecting host?
If you use an integrated monitoring database, execute the jimdbstatus command to check the status of the IM database service of the manager host. Confirm that the IM database service is running, and then retry the operation. If a KAVB8602-E message was output in the integrated trace log of the manager, take the corrective action given for that message.

KAVB0104-E


Failed to authenticate the user.

User authentication failed. The entered user name or password is incorrect.

S:
Waits for re-entry of information.

O:
Check the user name and password, and then retry the operation.

KAVB0105-E


Failed to authenticate the user.
Details:detailed-information

An incorrect authentication server name was set, or the host at the connection destination is incorrect.

S:
Waits for re-entry of information.

O:
Set the correct authentication server name in the environment settings.

KAVB0106-E


An error occurred in looking into the access authorization to JP1 resources.
Details:detailed-information

An error occurred while inquiring about permission to access JP1 resources.

S:
Waits for re-entry of information.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0107-E


Failed to obtain product information.
Details:detailed-information

An attempt to acquire product information failed.

S:
Waits for re-entry of information.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0108-E


An error occurred in the logout processing.
Connecting host:connecting-host
Details:detailed-information

An error occurred during logout processing.

S:
Waits for re-entry of information.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0109-E


Communication error occurred between the connecting host and the authentication server.
Connecting host:connecting-host

A communication error occurred between the connecting host and the authentication server.

S:
Waits for re-entry of information.

O:
Determine whether there is an error in the authentication server setting on the connecting host.

KAVB0121-E


Central Scope is not installed on the connection host.
Connection host:connecting-host

If the connecting host is JP1/IM - Central Console (version 07-00 to 07-01), JP1/IM - Central Scope is not installed.

If the connecting host is JP1/IM - Manager (version 08-00 or later), the setting to start Central Scope Service and to distribute events to Central Scope Service has not been enabled.

S:
Waits for re-entry of information.

O:
Check the following items, and then log in to the system again.
  • If the connection host is JP1/IM - Central Console (version 07-00 to 07-01), is JP1/IM - Central Scope installed on the connection host?
  • If the connection host is JP1/IM - Manager (version 08-00 or later), has the setting to start Central Scope Service and to distribute events to Central Scope Service been enabled at the connection host?

KAVB0122-I


Closing the windows makes you log out. Are you sure you want to log out?

Confirms that it is OK to log out.

O:
Click the Yes button to log out. Click the No button to cancel logout.

KAVB0123-W


Central Scope is writing a file, so logout is not possible. Wait until the file output is finished.

You cannot log out because JP1/IM - Manager is outputting a file.

S:
Aborts logout processing and displays the Monitoring Tree window in the foreground.

O:
Wait until JP1/IM - Manager finishes file output, and then log out.

KAVB0201-I


The event selected will be deleted. Are you sure you want to do this?

Confirms that it is OK to delete the selected event from the screen.

O:
Click the Yes button to delete the selected event from the screen. Click the No button to cancel deleting the selected event from the screen.

KAVB0204-I


Are you sure to log out?

Confirms that it is OK to log out.

O:
Click the Yes button to log out. Click the No button to cancel logout.

KAVB0207-W


Your user profile is set up incorrectly. (File:filename)
The default settings will be used.

The user profile has been defined incorrectly.

O:
Collect the user profile displayed in the message box, and then contact a system administrator.

KAVB0208-I


The selected events will be released. Do you want to continue?

Confirms that it is OK to release the selected severe event(s).

O:
Click the Yes button to release the selected severe event(s). Click the No button to cancel releasing the selected severe event(s).

KAVB0209-I


The status of the selected event will be changed to action-status.
Are you sure you want to do this?

Confirms that it is OK to change the selected event status to action-status.

O:
Click the Yes button to change the selected event status to action-status. Click the No button to cancel changing the selected event status to action-status.

KAVB0210-E


The conditions for input-information is either duplicated.

The same condition was specified more than once for an input item in the window.

When multiple conditions can be specified, you cannot specify the same condition more than once.

S:
Waits for re-entry of information.

O:
Carefully review the conditions, and then retry the operation.

KAVB0211-E


The conditions for input-information is either duplicated.
input-information:input-value

The same condition was specified more than once for an input item in the window.

When multiple conditions can be specified, you cannot specify the same condition more than once.

S:
Waits for re-entry of information.

O:
Enter the input item correctly.

KAVB0212-Q


One or more of the selected events was acquired while the integrated monitoring database was in an invalid state.
The selected events (not including any that were acquired while the integrated monitoring database was in an invalid state) will be changed to action-status.
Do you want to continue?

When changing the action status of the selected events, events were found that were acquired while the integrated monitoring database was invalid.

S:
If the Yes button is clicked, the system changes the status of events other than those that were acquired while the integrated monitoring database was invalid. If the No button is clicked, the system suspends processing.

O:
For events for which the status could not be changed, specify the event database for the search object, and then retry the operation.

KAVB0213-Q


One or more of the selected events was acquired while the integrated monitoring database was in an invalid state.
The selected events (not including any that were acquired while the integrated monitoring database was in an invalid state) will be deleted.
Do you want to continue?

One or more of the selected events was acquired while the integrated monitoring database was invalid.

S:
If the Yes button is clicked, the system changes the status of events other than those acquired while the integrated monitoring database was invalid. If the No button is clicked, the system suspends processing.

O:
Log in to the system again.

KAVB0214-Q


One or more of the selected events was acquired while the integrated monitoring database was in an invalid state.
The selected events (not including any that were acquired while the integrated monitoring database was in an invalid state) will be released.
Do you want to continue?

One or more of the selected events were acquired while the integrated monitoring database was invalid.

S:
If the Yes button is clicked, the system releases events other than those acquired while the integrated monitoring database was invalid. If the No button is clicked, the system suspends processing.

O:
Log in to the system again.

KAVB0216-E


The selected events were acquired while the integrated monitoring database was in an invalid state.
The statuses of these events cannot be changed.

When the status was changed, all selected events were found to be events acquired while the integrated monitoring database was invalid.

S:
Suspends processing.

O:
For events whose status could not be changed, search events by specifying the event database for the search object, and then retry the operation.

KAVB0217-E


The selected events were acquired while the integrated monitoring database was in an invalid state.
These events cannot be deleted.

All selected events were found to be events that were acquired while the integrated monitoring database was invalid.

S:
Suspends processing.

O:
Log in to the system again.

KAVB0218-E


The selected events were acquired while the integrated monitoring database was in an invalid state.
These events cannot be released.

All selected events were found to be events that were acquired while the integrated monitoring database was invalid.

S:
Suspends processing.

O:
Log in to the system again.

KAVB0219-E


The selected events were acquired while the integrated monitoring database was in an invalid state.
No information related to these events can be acquired.

All selected events were found to be events that were acquired while the integrated monitoring database was invalid.

S:
Suspends processing.

O:
For events that could not be displayed, search events by selecting the event database for the search object, and then retry the operation.

KAVB0221-E


A common extended attribute cannot be specified.

You can only specify a unique extended attribute.

S:
Waits for re-entry of information.

O:
Common extended attributes cannot be mapped because they can be displayed as display items. Specify a unique extended attribute.

KAVB0223-E


The mapping of the event information to the display item (display-item) of the event ID (event-ID) is already defined.

More than one mapping is set for one display item for one event.

S:
Waits for re-entry of information.

O:
Only one mapping can be set for one display item for one event. Carefully review the contents of the mapping destination display item and event ID to avoid duplicate mappings for one displayed item.

KAVB0227-W


Reflecting the settings into the manager will affect the JP1/IM - View linked to the manager. Are you sure you want to do this?

When applying the settings in the manager, events displayed in the connected JP1/IM - View may change.

O:
Click the Yes button to apply the settings. Click the No button to cancel applying the settings.

KAVB0228-E


The event-information mapping definition was reflected in the manager, but the attempt to save the definition failed. When the manager stops, the current settings will be lost.

The mapping definition was applied in the manager, but because save processing failed, the setting will be lost when the manager is stopped.

S:
Mapping is functional because it was applied in the manager, but the system aborts save processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0229-I


Are you sure you want to cancel the notification suppression of function-name?

Confirms that it is OK to release notification suppression.

O:
Click the Yes button to release notification suppression. Click the No button to cancel releasing notification suppression.

KAVB0230-E


An attempt to cancel the notification suppression of function-name has failed. (detailed code=code)

An attempt to cancel notification suppression failed.

S:
Aborts processing.

O:
Retry the operation. If the same message is displayed, collect data, and then contact a system administrator.

KAVB0231-E


An attempt to obtain the notification status has failed.

An attempt to acquire function notification status failed.

S:
Aborts processing.

O:
Refresh the display of the event list. If the same message is displayed, collect data, and then contact a system administrator.

KAVB0241-E


input-information is not a correct date or time information.

Date or time information entered in the window is incorrect.

S:
Waits for re-entry of information.

O:
Enter the correct date and time, and then retry the operation.

KAVB0243-E


The settings for an event ID is incorrect.
Specify the event ID in 8-digits hexadecimal number.

The event ID information entered in the window is incorrect.

S:
Waits for re-entry of information.

O:
Enter the correct event ID, and then retry the operation.

KAVB0244-E


The settings for an event ID is incorrect.
Specify the event ID in 8-digits hexadecimal number.
input-information: input-value

The event ID information entered in the window is incorrect.

S:
Waits for re-entry of information.

O:
Enter the correct event ID, and then retry the operation.

KAVB0245-E


Specify conditions for input-information.

No condition was set in the window for an item that requires setting of conditions.

S:
Waits for re-entry of information.

O:
Set conditions, and then retry the operation.

KAVB0246-E


The filter condition exceeds the maximum length. (Maximum length:maximum-length)

The total length of the filter condition statement set in the window exceeds the maximum length.

  • For event search: With JP1/Base (version 06-00 or earlier), the maximum length is 4,096 bytes, and with JP1/Base (version 06-51), the maximum length is 65,536 bytes.
  • For event acquisition filter: If an exclusion-condition group or common exclusion-condition group being applied has been set, the maximum length is 65,536 bytes; if not, it is 61,440 bytes.
  • For severe event(s) filter: 65,536 bytes
  • For user filter: 1,048,576 bytes
  • For view filter: 1,048,576 bytes

S:
Waits for re-entry of information.

O:
Set conditions again, and then retry the operation.

KAVB0247-E


input-information exceeds the maximum number of items that can be input. (Maximum number: maximum-number)

The specified conditions exceed the maximum number that can be entered for the item.

S:
Waits for re-entry of information.

O:
Set conditions again, and then retry the operation.

KAVB0248-E


The settings for a regular expression is incorrect.

The specified regular expression is incorrect.

S:
For event search, event search is not executed. In this case, the system closes the Event Search Conditions window and returns to the Event Console window.
In the following filter settings windows, a message dialog box appears and the system waits for re-entry of information.
  • Event acquisition filter
  • Severe event(s) filter
  • User filter
  • View filter

O:
Set conditions again, and then retry the operation.

KAVB0249-W


The filter condition exceeds the maximum length. (maximum-length)The filtercondition can beedited or deleted,but cannot be added or copied.

You cannot add to or copy the filter condition statement because the total length of the filter condition statement set in the window exceeds the maximum.

S:
Waits for re-entry of information.

O:
Set conditions again, and then retry the operation.

KAVB0250-I


Do you really want to delete this filter?

Confirms that it is OK to delete the selected filter.

O:
Click the Yes button to delete the selected filter. Click the No button to cancel deleting the selected filter.

KAVB0251-E


The search cannot be performed for the specified condition because the search host's JP1/Base does not support the exclusion condition.

Event search including the exclusion condition could not be performed because the search host's JP1/Base is earlier than version 08-50.

S:
The system does not perform event search.

O:
Check the JP1/Base version of the host specified as the event search execution host. To specify exclusion conditions, JP1/Base version 08-50 or later must have been installed.

KAVB0255-E


The common extended attribute is already defined.

The condition cannot be entered more than once because a unique extended attribute is entered using an AND condition.

S:
Waits for re-entry of information.

O:
Carefully review the conditions, and then reconfigure the settings.

KAVB0256-E


The specified condition group name already exists.

You cannot specify a condition group name more than once in the list of condition groups.

S:
Waits for re-entry of information.

O:
Set conditions again, and then retry the operation.

KAVB0257-I


Are you sure you want to delete this condition group?

Confirms that it is OK to delete the selected condition group(s).

O:
Click the Yes button to delete the selected condition group(s). Click the No button to cancel deleting the selected condition group(s).

KAVB0258-E


Specify the condition group name.

No condition group name was set.

S:
Waits for re-entry of information.

O:
Set a condition group name, and then retry the operation.

KAVB0259-E


The specified filter name already exists.

You cannot specify the same filter name more than once.

S:
Waits for re-entry of information.

O:
Set conditions again, and then retry the operation.

KAVB0260-E


A filter being applied cannot be deleted.

You cannot delete the specified filter because the filter is being applied.

S:
Terminates processing and returns to the Event Acquisition Conditions List window.

O:
Switch the filter being applied to another condition, and then retry the operation.

KAVB0261-I


The search is complete.

Reports the end of event search.

KAVB0262-I


The search reached the end of the event database.

Event search from the beginning to the end of the event database is complete. To search events that were registered later than the event database, click the Search for Next Event button.

S:
Terminates processing.

KAVB0263-I


The search reached the beginning of the event database.

Event search from the end to the beginning of the event database is complete.

S:
Terminates processing.

KAVB0264-I


The search is complete.

Event search for the number of events to acquire in one search is complete.

S:
Terminates processing.

KAVB0265-I


The search has reached the end of the Integrated Monitoring Database.

Event search from the beginning to the end of the integrated monitoring database is complete.

S:
Terminates processing.

KAVB0266-I


The search has reached the beginning of the Integrated Monitoring Database.

Event search from the end to the beginning of the integrated monitoring database is complete.

S:
Terminates processing.

KAVB0270-E


An attempt to switch the event acquisition filter failed for some controls.

An attempt to switch the event acquisition filter failed for some controls.

S:
Aborts switching of the event acquisition filter.

O:
Check the integrated trace log of the manager to see if an error message was output. If an error message was output, take the corrective action given for that message. If no message was output, use the data collection tool to collect data, and then contact a system administrator.

KAVB0271-E


An attempt to switch the event acquisition filter has failed.

An attempt to switch the event acquisition filter failed.

S:
Aborts switching of the event acquisition filter.

O:
Check the integrated trace log of the manager to see if an error message was output. If an error message was output, take the corrective action given for that message. If no message was output, use the data collection tool to collect data, and then contact a system administrator.

KAVB0281-E


The user(input-information) is either duplicated in a field or defined in another user's filter.

The same user was specified multiple times. Another possibility is that the user has already been defined for another user filter. You can define one user for one user filter.

S:
Waits for re-entry of information.

O:
Enter the target user name correctly, and then retry the operation.

KAVB0282-E


You cannot use a space character as a delimiter to specify input-information.

A space character was used incorrectly as a delimiter to specify multiple users. Use a comma as a delimiter to specify multiple users.

S:
Waits for re-entry of information.

O:
Correct the invalid space character entry, and then retry the operation.

KAVB0291-E


Failed to obtain detailed event information.

An unexpected error was detected while acquiring the detailed event information to be displayed from Central Console Manager.

S:
Aborts display of detailed event information.

O:
Collect the JP1/IM - View and JP1/IM - Manager data, and then contact a system administrator.

KAVB0292-I


Details cannot be displayed because no event is selected.

Detailed information cannot be displayed in the Event Details window because no event is selected in the Event Console window.

O:
Select an event in the Event Console window.

KAVB0293-I


Details cannot be displayed because multiple events are selected.

Detailed information cannot be displayed in the Event Details window because multiple events are selected in the Event Console window.

O:
Select one event in the Event Console window.

KAVB0301-E


System error occurred in Tool Launcher.

An unexpected error was detected during processing of the Tool Launcher window.

S:
Aborts processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0311-W


An event that is not in the manager was in the repeated events.

An event that is not in the manager was in the repeated events.

S:
Continues processing.

KAVB0312-E


The maximum number of events that can be changed at a time is the-maximum-number-of-scroll-buffers.
Please select the events again.

The maximum number of events for which the action status can be changed at one time is 2,000 in the Event Console window of JP1/IM - View and 1,000 in the Event Console window of the Web page version of JP1/IM - View. The total number of selected events (including non-consolidation events, consolidation events, and repeated events) exceeds the maximum number of events.

S:
Suspends processing. The system does not change the action status.

O:
Select events so that the total number of selected events (including non-consolidation events, consolidation events, and repeated events) is no more than 2,000 in the Event Console window of JP1/IM - View and no more than 1,000 in the Event Console window of the Web page version of JP1/IM - View.

KAVB0321-Q


Are you sure you want to save the CSV file now? (file=file-name)

Confirms that it is OK to save the file.

S:
If the Yes button is clicked, the system saves the file.
If the No button is clicked, the system does not save the file.

KAVB0322-Q


Are you sure you want to overwrite the existing CSV file? (file=file-name)

Confirms that it is OK to overwrite the file.

S:
If the Yes button is clicked, the system overwrites the file.
If the No button is clicked, the system does not overwrite the file.

KAVB0323-E


An attempt to open the CSV file has failed. (details = detailed-information)

An attempt to open the CSV file failed.

S:
Suspends CSV file output processing.

O:
Take the corrective action given for the detailed information, and then retry the CSV output operation. If the problem persists, use the data collection tool to collect data, and then contact a system administrator.

KAVB0324-E


An attempt to lock the CSV file has failed. (file=file-name)

An attempt to acquire exclusive permission for the file failed.

S:
Suspends CSV file output processing.

O:
Check the following items, and then retry the CSV output operation.
  • Is another application locking the file?
  • Is output being attempted simultaneously for another file?

KAVB0325-E


An attempt to output the CSV file has failed. (file=file-name)

An attempt to output the file failed.

S:
Suspends CSV file output processing.

O:
Make sure there is sufficient free space at the CSV file output destination, and then retry the CSV output operation.

KAVB0326-E


A memory shortage occurred during output of the CSV file. (file=file-name)

A memory shortage occurred during output of the CSV file.

S:
Suspends CSV file output processing.

O:
Make sure sufficient free space is allocated, and then retry the CSV output operation.

KAVB0327-E


The file cannot be saved because the file name is too long. (file=file-name)

The CSV file name in the absolute path exceeds 259 characters.

S:
Suspends CSV file output processing.

O:
Reduce the length of the file name in the absolute path to 259 characters or fewer, and then retry the CSV output operation.

KAVB0328-E


The file cannot be saved because of an invalid file name. (file=file-name)

The file cannot be saved because an invalid file name is used. Invalid file names are as follows:

  1. The name includes :, ?, ", <, >, or |.
  2. The name is a complete match to CON, PRN, AUX, NUL, COM1, COM2, COM3, COM4, COM5, COM6, COM7, COM8, COM9, LPT1, LPT2, LPT3, LPT4, LPT5, LPT6, LPT7, LPT8, or LPT9 (including lower case).
  3. In addition to 1 and 2 above, the file name includes .xxx (where xxx are any characters).
    Examples: CON.txt, PRN.txt.csv

S:
Suspends CSV file output processing.

O:
Change the file name, and then retry the CSV output operation.

KAVB0329-E


An I/O error occurred during output of the CSV file. (file=file-name)

An I/O error occurred during output of the CSV file.

S:
Suspends CSV file output processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0341-W


The event database on host-name does not contain the related event. (serial number=serial-number-in-event-database)

An attempt was made to display a related event that does not exist in the event database of the host name.

This message is displayed when a new event exceeds the capacity of the event database on the manager, or when the event database is deleted.

S:
Continues displaying the related event.

O:
Check the following items:
  • Has the event database been deleted?
  • Is the capacity of the event database a small value?

KAVB0342-W


The related event cannot be displayed because it is filtered by the user filter. (serial number in the event database= serial-number-in-event-database)

An attempt was made to display a related event that could not be displayed because it was filtered by the user filter.

S:
Continues processing.

O:
Carefully review the user filter conditions.

KAVB0343-E


A system error occurred on the server during acquisition of the related event. (server name = server-name, reason = reason)

A system error occurred on the server during acquisition of the related event.

S:
Suspends acquisition of the related event.

O:
Determine whether an error has occurred in the network.
If there is no error in the network, use the data collection tool to collect data, and then contact a system administrator.

KAVB0344-E


A memory shortage occurred on the server during acquisition of the related event. (server name = server-name)

A memory shortage occurred on the server during acquisition of the related event.

S:
Suspends acquisition of the related event.

O:
Make sure sufficient free space is allocated.
If there is no memory shortage, use the data collection tool to collect data, and then contact a system administrator.

KAVB0345-E


The event buffer on the server cannot accept the acquisition of the related event. (server name = server-name)

The event buffer on the server is not in a status in which it can accept acquisition of the related event.

S:
Suspends acquisition of the related event.

O:
Wait awhile, and then retry the operation.

KAVB0346-E


A system error occurred while acquiring the related event from the event service on host-name. (reason = reason)

A system error occurred while acquiring the related event from Event Service on host-name.

S:
Suspends acquisition of the related event.

O:
Determine whether Event Service is running.
If Event Service is not running, start Event Service, and then restart the manager to recover from the error.
If the cause of the problem cannot be identified, use the data collection tool to collect data, and then contact a system administrator.

KAVB0347-E


The related event could not be acquired because it was not possible to connect to the event service on host-name.

Connection between the manager and event service cannot be established.

S:
Suspends acquisition of the related event.

O:
Determine whether Event Service is running.
If Event Service is not running, start Event Service, and then restart the manager to recover from the error.

KAVB0349-E


The related event could not be acquired because a communication error occurred with the event service on host-name.

A communication error occurred while the related event was acquired from Event Service on host-name. The possible causes are as follows:

  • The manager is not running.
  • Event Service is not running.
  • The processing request load is temporarily high.

S:
Suspends acquisition of the related event.

O:
Take corrective action as follows according to the cause of the error.
  • Confirm that the manager is running.
  • Confirm that Event Service is running.
  • Retry the operation. If the operation is not successful after the specified number of retries, restart the viewer, and then retry the operation.

KAVB0350-W


Manager host identification processing failed. The status of the related event cannot be changed.

The action status cannot be changed because the host from which the related event is acquired and the manager host cannot be identified.

S:
Displays the related event but does not change the action status for the displayed related event.

O:
Confirm that communication is established with the host that issues the display target event, and then retry the operation. If the system still cannot recover, use the data collection tool to collect data, and then contact a system administrator.

KAVB0351-E


The related event cannot be displayed because the data necessary for acquiring the event is not present.

The related event cannot be displayed because an internal error occurred.

S:
Continues processing without displaying the related event.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0352-E


The related event could not be acquired because an error occurred. (serial number in the event database = serial-number-in-event-database)

The related event could not be acquired because an error occurred.

S:
Suspends acquisition of the related event.

O:
Check the message displayed in the dialog box or output in the integrated trace log, and take the corrective action given for that message.

KAVB0353-W


The integrated monitoring database on host-name does not contain a related event. (serial number = serial-number-in-event-database)

An attempt was made to display a related event that does not exist in the integrated monitoring database on host-name.

This message is displayed when a new event exceeds the capacity of the event database on the manager, or the status of the integrated monitoring database is changed from valid to invalid, or vice versa, during correlation or consolidation.

S:
Continues displaying the related event.

O:
If the status of the integrated monitoring database was changed from valid to invalid, log in to the system again.

KAVB0361-E


An attempt to copy to the clipboard failed because the clipboard is full (bytes bytes).

An attempt to copy to the clipboard failed because the information copied to the clipboard exceeds the limit value (bytes).

S:
Suspends copying to the clipboard.

O:
Reduce the number of selected items, and then retry the operation.

KAVB0362-E


An attempt to copy to the clipboard failed because the clipboard is being used.

An attempt to copy to the clipboard failed because another application is using the clipboard.

S:
Suspends copying to the clipboard.

O:
Make sure that another application is not using the clipboard, and then retry the operation.

KAVB0363-E


A memory shortage occurred during processing to copy to the clipboard.

A memory shortage occurred during copying to the clipboard.

S:
Suspends copying to the clipboard.

O:
Make sure sufficient free space is allocated, and then retry the operation.

KAVB0364-E


An attempt to copy to the clipboard has failed. (reason = reason)

An attempt to copy to the clipboard failed.

S:
Suspends copying to the clipboard.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0368-W


There are no events in the integrated monitoring database that were registered before the specified period.

No events in the integrated monitoring database were registered before the specified period because the viewer host's start time is later than the manager host's start time.

S:
Disables the event display start-time specification area and continues processing.

O:
The viewer host's start time is later than the manager host's start time. Carefully review the setting of the viewer host's start time.

KAVB0371-E


The IM-View configuration file does not exist.

There is no IM - View configuration file.

S:
Continues processing using the default value.

O:
Check the definition file, and then restart JP1/IM - View. If there is no error in the definition file, use the data collection tool to collect data, and then contact a system administrator.

KAVB0372-E


An attempt to read the IM-View configuration file has failed. (reason = reason)

An attempt to read the IM - View configuration file failed.

S:
Continues processing using the default value.

O:
Confirm that the access permission is set correctly, and then restart JP1/IM - View. If there is no error in the definition file, use the data collection tool to collect data, and then contact a system administrator.

KAVB0373-E


A value defined for an item (item-name) in the IM-View configuration file is invalid. The default value (default-value) will be used.

A value defined for an item in the IM - View configuration file indicated in the message is incorrect.

S:
Continues processing using the default value indicated in the message.

O:
Correct the value in the IM - View configuration file, and then restart JP1/IM - View.

KAVB0374-E


A value defined for an item (item-name) in the IM-View configuration file is outside the valid range. The default value (default-value) will be used.

A value defined for an item in the IM - View configuration file indicated in the message is outside the valid range.

S:
Continues processing using the default value indicated in the message.

O:
Correct the value in the IM - View configuration file, and then restart JP1/IM - View.

KAVB0381-W


An error occurred during initialization processing necessary for outputting to the integrated trace log.

An error occurred during initialization processing for output to the integrated trace log. The message cannot be output to the integrated trace log.

S:
Continues processing.

O:
Determine whether the following service is running.
  • Hitachi Network Objectplaza Trace Monitor 2
If the service is not running, start the service, and then restart JP1/IM - View.
If the service is running, close the message box, and then restart JP1/IM - View.
If the same message is displayed, use the data collection tool to collect data, and then contact a system administrator.

KAVB0391-E


The definition of the settings file(file-name) for consolidated display of repeated events is invalid. (Maintenance information = maintenance-information)

An invalid value is set in the settings file (file-name) for consolidated display of repeated events.

S:
Stops reading data from the settings file for consolidated display of repeated events and continues processing without the settings in the settings file for consolidated display of repeated events.

O:
In the Preferences window, reconfigure the consolidated display of repeated events.
Alternatively, if the settings file for consolidated display of repeated events has been backed up, stop JP1/IM - Manager, restore the settings file, and then restart JP1/IM - Manager.
If the problem persists, use the data collection tool to collect data, and then contact a system administrator.

KAVB0392-E


The definition of the view filter definition file(file-name) is invalid. (maintenance information = maintenance-information)

An invalid value is set in the view filter definition file.

S:
Stops reading data from the view filter definition file and continues processing without the settings of the view filter.

O:
In the View List of Filters window, reconfigure the view filter.
Alternatively, if the view filter definition file (file-name) has been backed up, stop JP1/IM - Manager, restore the definition file, and then restart JP1/IM - Manager.
If the problem persists, use the data collection tool to collect data, and then contact a system administrator.

KAVB0393-E


The definition of the event acquisition filter definition file(file-name) is invalid. (maintenance information = maintenance-information)

An invalid value is set in the event acquisition filter definition file.

S:
Stops reading data from the event acquisition filter definition file and continues processing. The System Environment Settings window can no longer be started from JP1/IM - View.

O:
If the event acquisition filter definition file (file-name) has been backed up, stop JP1/IM - Manager, restore the definition file, and then restart JP1/IM - Manager.
If the event acquisition filter definition file has not been backed up, stop JP1/IM - Manager, and then use the following procedure to restore the initial status of the event acquisition filter (the filter that acquires events other than JP1/SES events). After that, start JP1/IM - Manager and reconfigure the event acquisition filter.
To restore the initial status of the event acquisition filter:

In Windows:
Restoring the physical host:
cd console_path\conf\console\filter
copy receive_filter.conf.model receive_filter.conf
Restoring the logical host:
cd shared_folder\jp1cons\conf\console\filter
copy receive_filter.conf.model receive_filter.conf

In UNIX:
Restoring the physical host:
cd /etc/opt/jp1cons/conf/console/filter
cp -p receive_filter.conf.model receive_filter.conf
Restoring the logical host:
cd common-directory/jp1cons/conf/console/filter
cp -p receive_filter.conf.model receive_filter.conf
If the problem persists, use the data collection tool to collect data, and then contact a system administrator.

KAVB0394-E


The definition of the event acquisition filter list file(file-name) is invalid. (maintenance information = maintenance-information)

An invalid value is set in the storage file for the event acquisition filter lists.

S:
Stops reading data from the storage file for event acquisition filter lists and continues processing. The System Environment Settings window can no longer be started from JP1/IM - View.

O:
If the storage file for event acquisition filter lists (file-name) has been backed up, stop JP1/IM - Manager, restore the storage file, and then restart JP1/IM - Manager.
If the storage file for event acquisition filter lists has not been backed up, stop JP1/IM - Manager, and then use the following procedure to delete the storage file for event acquisition filter lists. After that, start JP1/IM - Manager and reconfigure the event acquisition filter.
To delete the storage file for event acquisition filter lists:

In Windows:
Deleting the physical host:
cd console_path\conf\console\filter
del file-name (receive_filter_list.conf)
Deleting the logical host:
cd common_folder\jp1cons\conf\console\filter
del file-name (receive_filter_list.conf)

In UNIX:
Deleting the physical host:
cd /etc/opt/jp1cons/conf/console/filter
rm file-name (receive_filter_list.conf)
Deleting the logical host:
cd shared_directory/jp1cons/conf/console/filter
rm file-name (receive_filter_list.conf)
If the problem persists, use the data collection tool to collect data, and then contact a system administrator.

KAVB0395-E


The definition of the event search filter definition file(file-name) is invalid. (maintenance information = maintenance-information)

An invalid value is set in the event search filter definition file.

S:
Stops reading data from the event search filter definition file and continues processing without the event search condition settings.

O:
In the Event Search Conditions window, set the event search condition again.
Alternatively, if the event search filter definition file (file-name) has been backed up, stop JP1/IM - Manager, restore the definition file, and then restart JP1/IM - Manager.
If the problem persists, use the data collection tool to collect data, and then contact a system administrator.

KAVB0396-E


The definition of the severe event(s) filter definition file(file-name) is invalid. (maintenance information = maintenance-information)

An invalid value is set in the event acquisition filter definition file.

S:
Terminates Event Console Service.

O:
If the severe event(s) filter definition file (file-name) has been backed up, stop JP1/IM - Manager, restore the definition file, and then restart JP1/IM - Manager.
If the severe event(s) filter definition file has not been backed up, stop JP1/IM - Manager, and then use the following procedure to delete the severe event(s) filter definition file. After that, start JP1/IM - Manager and reconfigure the severe event(s) filter.
To delete the severe event(s) definition file:

In Windows:
Deleting the physical host:
cd console_path\conf\console\filter
del file-name (serious_filter_ex.conf)
Deleting the logical host:
cd shared_folder\jp1cons\conf\console\filter
del file-name (serious_filter_ex.conf)

In UNIX:
Deleting the physical host:
cd /etc/opt/jp1cons/conf/console/filter
rm file-name (serious_filter_ex.conf)
Deleting the logical host:
cd shared_directory/jp1cons/conf/console/filter
rm file-name (serious_filter_ex.conf)
If the problem persists, use the data collection tool to collect data, and then contact a system administrator.

KAVB0397-E


The definition of the event receiver filter definition file(file-name) is invalid. (maintenance information = maintenance-information)

An invalid value is set in the user filter definition file.

S:
Terminates Event Console Service.

O:
If the user filter definition file (file-name) has been backed up, stop JP1/IM - Manager, restore the definition file, and then restart JP1/IM - Manager.
If the user filter definition file has not been backed up, stop JP1/IM - Manager, and then use the following procedure to delete the user filter definition file. After that, start JP1/IM - Manager and reconfigure the user filter.
To delete the user filter definition file:

In Windows:
Deleting the physical host:
cd console_path\conf\console\filter
del file-name (user_filter_ex.conf)
Deleting the logical host:
cd shared_folder\jp1cons\conf\console\filter
del file-name (user_filter_ex.conf)

In UNIX:
Deleting the physical host:
cd /etc/opt/jp1cons/conf/console/filter
rm file-name (user_filter_ex.conf)
Deleting the logical host:
cd shared_directory/jp1cons/conf/console/filter
rm file-name (user_filter_ex.conf)
If the problem persists, use the data collection tool to collect data, and then contact a system administrator.

KAVB0401-E


System error occurred in the command execution screen.

An unexpected error was detected during processing of the Execute Command window.

S:
Aborts processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0411-E


Cannot initialize the command execution session.
Reason:reason

An error was detected during command execution session initialization.

S:
Aborts processing.

O:
Check the following items depending on the reason that is displayed:
  • The port number is invalid.
    Check the specified port number.
  • Fail to connect JP1/Base.
    An attempt to connect to JP1/Base of the connected server failed. JP1/Base of the connected server may not be running. Check the connected server status. Also, a communication error may have occurred. Check the status of the connection with the server.
  • Connection has timed out.
    A time-out occurred due to a high load on the server or network. Wait awhile, and then retry the operation.
  • There is a bad response from the server.
  • Socket error occurred.
  • Connection has failed.
    A communication error occurred. Check the status of the connection with the server.
  • Reasons other than the above
    Use the data collection tool to collect data, and then contact a system administrator.

KAVB0412-E


An error occurred in terminating the command execution session.
Reason:reason

An error was detected during termination of the command execution session.

S:
Aborts processing.

O:
Refer to the KAVB0411-E message.

KAVB0413-E


An error occurred in executing the command.
Reason:reason

An error was detected in the command execution session during execution of a command.

S:
Aborts command processing.

O:
Check the following items depending on the reason that is displayed:
  • The length of the hostname is incorrect.
  • The length of the command is incorrect.
  • The length of the environment parameter is incorrect.
    Check the length of the value you entered, and then try again.
For other than the above, refer to the KAVB0411-E message.

KAVB0414-E


An error occurred while receiving the execution result of command.
Reason:reason

An error was detected in the command execution session during reception of the command execution result. The execution result of the command being executed or the preceding command cannot be acquired.

S:
Aborts processing.

O:
Refer to the KAVB0411-E message.

KAVB0451-W


Failed to read the input history.

An attempt to read the input history failed.

S:
Continues processing without the input history information.

KAVB0452-W


Failed to save the input history.

An attempt to write the input history failed.

S:
Continues processing without the input history information.

KAVB0502-I


Are you sure to close without pressing the "Apply" button?

The settings are not valid until you click the Apply button. You are closing the window without clicking the Apply button.

If you click the Yes button, the window is closed without applying the settings. If you click the No button, the window remains open.

O:
Click the Yes button to close the window without applying the settings. Click the No button to cancel closing the window.

KAVB0503-I


Are you sure to delete this line?

Confirms that it is OK to delete the selected line.

O:
Click the Yes button to delete the selected line. Click the No button to cancel deleting the selected line.

KAVB0504-E


Failed to obtain the result of an action.

An attempt to acquire the action result information failed.

S:
Aborts processing.

O:
Perform the operation again.

KAVB0505-E


Failed to read/write/update the action definition.

An attempt to read, write, or update the action definition failed.

S:
Aborts processing.

O:
Perform the operation again.

KAVB0507-E


Do not input \ at the end of an action.

A backslash (\) was entered at the end of the action.

S:
Waits for re-entry of information.

O:
Carefully review the action to be input, and then perform the operation again.

KAVB0508-E


The settings for setting-item are incorrect.

The settings for setting-item are incorrect.

S:
Waits for re-entry of information.

O:
Perform the operation again.

KAVB0509-E


The extended attribute name was specified incorrectly.
You can use capital letters, numerics, and underlines only.
The name must begin with a capital letter.

The extended attribute was specified incorrectly.

S:
Waits for re-entry of information.

O:
Perform the operation again.

KAVB0510-E


You can specify up to 100 discretionary extend attributes.

The number of specified extended attributes exceeds 100 items.

S:
Waits for re-entry of information.

O:
Specify a maximum of 100 extended attributes.

KAVB0511-E


An action name is duplicated.

An action with the same action name has already been set.

You cannot specify an action name that is already being used.

S:
Waits for re-entry of information.

O:
Specify the action name again, and then retry the operation.

KAVB0512-E


The combination of comparison conditions among multiple event attributes that have the same name is invalid.

The combination of comparison keywords of event conditions for multiple attributes is invalid.

S:
Waits for re-entry of information.

O:
Specify another event condition, and then retry the operation.

KAVB0513-Q


One or more event conditions have not been set up.
The event conditions that have not been set up will be excluded. Do you want to continue?

Confirms that it is OK to exclude unspecified event conditions.

S:
If the Yes button is clicked, the system excludes the unspecified event conditions and continues processing.
If the No button is clicked, the system suspends processing.

O:
Delete the unspecified event conditions, or specify event conditions.

KAVB0514-E


The total number of characters (bytes) in the operands exceeds the maximum (maximum-length).

The total length of the attribute value of the specified event condition exceeds the maximum length.

S:
Waits for re-entry of information.

O:
Specify the event condition again, and then retry the operation.

KAVB0515-E


When you specify an execution-option, specify an action.

You specified an execution option without specifying an action.

S:
Waits for re-entry of information.

O:
Carefully review the execution details, and then retry the operation.

KAVB0516-E


The number of characters (bytes) in the operands exceeds the maximum (maximum-length).

The attribute value of the specified event condition exceeds the maximum length.

S:
Waits for re-entry of information.

O:
Specify the event condition again, and then retry the operation.

KAVB0531-I


Are you sure to require re-execution?

Confirms that it is OK to send a request for re-execution to the selected automated action.

O:
Click the Yes button to send the request for re-execution. Click the No button to cancel sending the request for re-execution.

KAVB0532-I


The list of action results was updated.

Updating of the list of action results finished normally.

KAVB0533-I


No action result corresponds to the update setting.

There is no action result that corresponds to the update condition.

The possible causes are as follows:

  • There is no action result that corresponds to the update condition.
  • The information in the action information file was overwritten.

O:
Carefully review the update condition.
If the update condition is correct, carefully review the capacity of the action information file.

KAVB0535-I


The cancel request will be executed. Is this OK?

Confirms that it is OK to send a cancel request to the selected automated action.

O:
Click the Yes button to send the cancel request. Click the No button to cancel sending the cancel request.

KAVB0536-I


The action is not in a re-executable state. Click the Refresh button in the window-title window, and then check the status.

After re-execution of an action, re-execution of the action was requested again before you clicked the Refresh button. Another possibility is that the action cannot be re-executed because the data for that action does not exist in the action information file.

S:
Aborts processing.

O:
Click the Refresh button in window-title to check the latest action status.

KAVB0540-E


The rule cannot be specified for the action.

You cannot manually specify <RULE> in the action specification area because it is an action for a rule startup request.

S:
Waits for re-entry of information.

O:
Specify the input item correctly.

KAVB0541-E


An attempt to start the Rule Log Details window of JP1/IM - Rule Operation has failed.

An attempt to open the Rule Log Details window of JP1/IM - Rule Operation failed.

S:
Does not open the Rule Log Details window of JP1/IM - Rule Operation.

O:
Retry the operation. If the same message is displayed, use the data collection tool to collect data, and then contact a system administrator.

KAVB0601-E


System error occurred in analyzing the definition.

An unexpected error was detected during processing of the definition information analysis.

S:
Aborts processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0602-E


Memory shortage occurred in analyzing the definition.

A memory shortage occurred during processing of the definition information analysis.

S:
Aborts processing.

O:
Allocate sufficient memory, and then retry the operation.

KAVB0611-E


Failed to execute the application.
Command name :executed-command
Details:detailed-information

An error occurred during execution of the application.

S:
Aborts application processing.

O:
Make sure that the execution path name and access permission specified in the definition file are correct, and then retry the operation.

KAVB0612-E


Failed to execute the application due to error in command line specifications.
Command Name : executed-command

An error occurred during generation of the command line.

S:
Aborts application processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0624-W


A failure occurred in obtaining the application(application-execution-ID) output-destination result.
Details: detailed-information

An error occurred during processing to acquire the application execution result.

S:
Aborts acquisition of the application execution result.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0651-W


The block(identifier) is multiply specified. The newer block is effective. (definition-file-name: line-number)

A block that defines the same identifier is specified multiple times.

S:
Invalidates the previously defined block, validates the new block, and continues analysis processing.

O:
Check the specification of the identifier, and then retry the operation.

KAVB0652-W


An invalid descriptor (identifier) is specified. processing-contents (definition-file-name:line-number)

An invalid identifier is specified. The possible causes are as follows:

  • An identifier that is already registered in the system is specified.
    default_browser, root
  • No identifier is specified.

S:
Executes processing-contents and continues analysis processing.

O:
Check the specification of the identifier, and then retry the operation.

KAVB0653-W


An invalid path name (path-name) is specified. processing-contents (definition-file-name:line-number)

The specified path name or file does not exist.

S:
Executes processing-contents and continues analysis processing.

O:
Check the specification of the path name, and then retry the operation.
However, if the message is output because the linkage product is not installed, corrective action is not necessary.

KAVB0654-W


Failed to convert the registry definition (registry-definition). processing-contents (definition-file-name:line-number)

Conversion of the registry failed.

S:
Executes processing-contents and continues analysis processing.

O:
Check the specification of the registry, and then retry the operation.

KAVB0655-W


The descriptor(identifier) specified is not defined. processing-contents (definition-file-name:line-number)

The specified identifier is not defined.

S:
Executes processing-contents and continues analysis processing.

O:
Check the block definition in the application definition file or function menu definition file, and then retry the operation.
However, if the message is output because the linkage product is not installed, corrective action is not necessary.

KAVB0656-W


The application execution definition is not specified for the block (identifier). processing-contents (definition-file-name:line-number)

The application execution definition is not specified for the specified definition block.

S:
Invalidates the definition block and continues analysis processing.

O:
Specify the application execution definition for the definition block, and then retry the operation.
However, if the message is output because the linkage product is not installed, corrective action is not necessary.

KAVB0657-W


The default browser is not registered.

The default Web browser is not registered.

S:
Invalidates the default Web browser definition and continues analysis processing.

O:
Assign a Web browser to the extension (html), and then retry the operation.

KAVB0658-W


Failed to read the image file.

An attempt to read the image file failed.

S:
Continues processing without displaying the image.

O:
Check the image file name specified in the definition file, and then retry the operation.

KAVB0711-E


More than 10 AND conditions have been specified. (line = line-number, file = file-name)

More than 10 AND conditions have been specified.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0712-E


An ampersand (&) cannot be specified for a parameter group of an action block at the front of an AND condition. (line = line-number, file = file-name)

You cannot specify an ampersand (&) for a parameter group of an action block at the front of an AND condition.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0713-E


More than 256 event conditions have been specified. (action = action-name, line = line-number, file = file-name)

More than 256 event conditions have been specified.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0714-E


The parameter parameter-name cannot be specified because a rule has been specified for the action. (action = action-name, line = line-number, file = file-name)

If you have specified an action for rule startup, you cannot specify a user name, target host name/group name, or environment variable file name.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0715-E


The location of the version of the automatic action definition file is invalid. (line = line-number, file = file-name)

The version of the automated action definition file is specified in a location other than the beginning of the file.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0716-E


The version information for the automatic action definition file is invalid. (line = line-number, file = file-name)

The version information is invalid.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0717-E


The parameter parameter is missing. (action = action-name, line = line-number, file = file-name)

The parameter is not specified.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0718-E


The shared block has been duplicated. (line = line-number, file = file-name)

The shared block is duplicated.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0719-E


An invalid parameter is specified. (invalid parameter = parameter-name, line = line-number, file = file-name)

An invalid parameter is specified in the automated action definition file.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0720-E


An invalid parameter is specified in an action block. (action = action-name, invalid parameter = parameter-name, line = line-number, file = file-name)

An invalid parameter is specified in an action block.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0721-E


An action block does not end with an "end-act" statement. (action = action-name, line = line-number, file = file-name)

An action block does not have an end.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0722-E


An action name is not specified. (line = line-number, file = file-name)

An action name is not specified.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0723-E


If an ampersand (&) is specified in a parameter group, an action name cannot be specified. (action = action-name, line = line-number, file = file-name)

If you specify an ampersand (&) in a parameter group, you cannot specify an action name.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0724-E


An action name is duplicated. (action = action-name, line = line-number, file = file-name)

An action name is duplicated.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0725-E


An action name exceeds the maximum length. (line = line-number, file = file-name)

An action name exceeds the maximum length.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0726-E


The parameter parameter-name is invalid. (action = action-name, line = line-number, file = file-name)

The description of the displayed parameter is unsuitable.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0727-E


No value is specified for the parameter parameter-name. (action = action-name, line = line-number, file = file-name)

No value is specified following the displayed parameter.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0728-E


The parameter parameter-name is specified more than once. (action = action-name, line = line-number, file = file-name)

The displayed parameter is specified more than once.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0729-E


No value is specified for the parameter parameter-name. (action = action-name, line = line-number, file = file-name)

No value is specified following the displayed parameter.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0730-E


The parameter parameter-name is specified more than once. (action = action-name, line = line-number, file = file-name)

The displayed parameter is specified more than once.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0731-E


The number of characters (bytes) in the parameter parameter-name exceeds the maximum. (action = action-name, line = line-number, file = file-name)

The value of the displayed parameter exceeds the maximum number of bytes.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0732-E


The number of characters (bytes) in the parameter parameter-name exceeds the maximum. (action = action-name, line = line-number, file = file-name)

The value of the displayed parameter exceeds the maximum number of bytes.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0733-E


An event condition block does not end with an "end-act" statement. (action = action-name, line = line-number, file = file-name)

An event condition block does not have an end.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0734-E


The event condition block is invalid. (action = action-name, line = line-number, file = file-name)

The description of the event condition is unsuitable.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0735-E


The event condition block attribute name is invalid. (attribute name = attribute-name, action = action-name, line = line-number, file = file-name)

The attribute name of the event condition is unsuitable.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0736-E


The attribute name is not specifiable. (attribute name = attribute-name, action = action-name, line = line-number, file = file-name)

An attribute name that cannot be specified was specified.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0737-E


The comparison key word for the event conditions is invalid. (attribute name = attribute-name, comparison key word = comparison-keyword, action = action-name, line = line-number, file = file-name)

The comparison keyword of the event condition is unsuitable.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0738-E


The comparison key word is not specifiable. (attribute name = attribute-name, comparison key word = comparison-keyword, action = action-name, line = line-number, file = file-name)

A comparison keyword that cannot be specified is specified.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0739-E


The number of event condition operands exceeds the maximum number. (attribute name = attribute-name, action = action-name, line = line-number, file = file-name)

The number of event condition operands exceeds the maximum.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0740-E


An event condition operand is duplicated. (attribute name = attribute-name, operand = operand, action = action-name, line = line-number, file = file-name)

An event condition operand is duplicated.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0741-E


An event ID operand is invalid. (operand = operand, action = action-name, line = line-number, file = file-name)

An event ID operand is unsuitable.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0742-E


A regular expression is invalid. (attribute name = attribute-name, operand = operand, action = action-name, line = line-number, file = file-name)

The specification of a regular expression is unsuitable.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0743-E


A critical operand is invalid. (operand = operand, action = action-name, line = line-number, file = file-name)

A critical operand is unusable.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0744-E


An operand is invalid. (attribute name = attribute-name, operand = operand, action = action-name, line = line-number, file = file-name)

An operand is unusable.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0745-E


The combination of comparison conditions among multiple event attributes that have the same name is invalid. (attribute = attribute-name, action = action-name, line = line-number, file = file-name)

The combination of comparison conditions among multiple event attributes that have the same name is invalid.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0746-E


The number of characters (bytes) in an operand exceeds the maximum. (attribute name = attribute-name, action = action-name, line = line-number, file = file-name)

The operand exceeds the maximum number of bytes.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0747-E


The total number of characters (bytes) in the operands exceeds the maximum. (action = action-name, line = line-number, file = file-name)

The total number of bytes in the operands exceeds the maximum.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0748-E


The specified value for the parameter parameter-name is outside the valid range. (specified value = specified-value, action = action-name, line = line-number, file = file-name)

The value specified for the displayed parameter is outside the valid range.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0749-E


If an ampersand (&) is specified in a parameter group, det cannot be specified. (action = action-name, line = line-number, file = file-name)

If you specify an ampersand (&) in a parameter group, you cannot specify det.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0750-E


Version information of an action definition file is specified more than once. (line = line-number, file = file-name)

Version information of an action definition file is specified multiple times.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0751-E


A shared block is specified after an action block. (line = line-number, file = file-name)

A shared block is specified after an action block.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0752-E


A shared block does not end with an "end-act" statement. (line = line-number, file = file-name)

A shared block does not have an end.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0753-E


An invalid parameter is specified for a shared block. (invalid parameter = parameter-name, line = line-number, file = file-name)

An invalid parameter is specified for a shared block.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0754-E


The parameter parameter-name is specified more than once. (line = line-number, file = file-name)

The displayed parameter is specified more than once.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0755-E


No value is specified for the parameter parameter-name. (line = line-number, file = file-name)

No value is specified following the displayed parameter.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0756-E


The parameter parameter-name is invalid. (line = line-number, file = file-name)

The description of the displayed parameter is unusable.

S:
Terminates processing.

O:
Correct the automated action definition file of the manager, and then perform the operation again.

KAVB0757-E


An error occurred while reading a action definition file. (reason = reason, line = line-number, file = file-name)

An unexpected error occurred while reading a definition file.

S:
Terminates processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0758-E


The size of the action definition file exceeds the upper limit. (file name: file-name, upper limit = maximum-size)

The size of the action definition file exceeds the maximum value.

S:
Terminates processing without reading the action definition file.

O:
Carefully review the contents of the action definition file to see if it contains extra comments or redundant definitions, and correct the file so that its size is no greater than the maximum value. After correcting the file, retry the operation.

KAVB0801-E


The option (option) is invalid.

An invalid option is specified.

S:
Terminates processing.

O:
Specify the option correctly.

KAVB0802-E


An essential option (option) is not specified.

A required option is not specified.

S:
Terminates processing.

O:
Specify the option correctly.

KAVB0803-E


The option (option) is duplicated.

The option is specified more than once.

S:
Terminates processing.

O:
Specify the option correctly.

KAVB0804-E


The argument of the option (option) is insufficient.

The argument of the option is insufficient.

S:
Terminates processing.

O:
Carefully review the specified argument.

KAVB0805-E


The argument value (argument) of the option (option) is invalid.

The argument value of the option is incorrect.

S:
Terminates processing.

O:
Specify the value of the option correctly.

KAVB0806-E


The maximum number of serial numbers in the event DB is 10. (Option : option)

The number of serial numbers in the event database specified by the option exceeds 10.

S:
Terminates processing.

O:
Reduce the number of specified serial numbers in the event database to no more than 10.

KAVB0807-E


The option option and the option option cannot be specified at the same time.

Processing cannot be executed because options that cannot be specified at the same time are specified.

S:
Terminates processing.

O:
Specify the options correctly.

KAVB0810-E


Specify an argument (argument-value) after the option (option).

Processing cannot be executed because an argument value is not specified following the displayed option.

S:
Terminates processing.

O:
Specify an argument value following the displayed option.

KAVB0811-E


When you specify a password, specify a host_name and a user_name.

To specify a password, also specify a host name and user name.

S:
Terminates processing.

O:
When specifying a password, specify a host name and user name as well.

KAVB0821-E


The manager does not have the specified event. (Serial number: serial-number-in-event-database)
The corresponding status of following events could not be changed.

The specified event does not exist in the manager. The action statuses after this event are not changed.

S:
Terminates processing.

KAVB0822-E


The event status of the specified event (Serial number: serial-number-in-event-database) could not be changed.
The corresponding status of following events could not be changed.

The action status of the specified event could not be applied in the manager. The action statuses after this event are not changed.

S:
Terminates processing.

O:
  • Determine whether Event Service is running.
    If Event Service is not running, start Event Service, and then retry the operation.
  • If you are using an integrated monitoring database, check the integrated trace log of the manager to see if any of the following messages was output. If a message was output, take the corrective action given for that message.
    [Figure] KAVB1663-E
    [Figure] KAVB1664-E
    [Figure] KAVB1665-E
    [Figure] KAVB1674-E
    [Figure] KAVB1675-E
    [Figure] KAVB1676-E
    If no message is output, contact a system administrator.

KAVB0823-E


The specified key (key-value) is invalid. Check the specified value.

The specified key value is incorrect.

S:
Terminates processing.

O:
Specify the key value correctly.

KAVB0824-E


The specified event is not an updateable event. (Serial number :serial-number-in-event-database)
This command will now stop.

An event that cannot be updated is specified.

S:
Terminates processing.

O:
Carefully review the specification of the serial numbers in the event database.

KAVB0825-E


A memory shortage occurred during execution of the command. (command-name)

A memory shortage occurred during execution of the command.

S:
Terminates processing.

O:
Allocate sufficient memory to execute the command, and then re-execute analysis processing.

KAVB0826-E


An exception occurred while the log output was being prepared.

A system error occurred while executing the command.

S:
Terminates processing.

O:
Collect the trace information output to standard error, use the data collection tool to collect data, and then contact a system administrator.

KAVB0827-E


An exception occurred while an error message was being created.

An unexpected exception occurred while an error message was being created.

S:
Terminates processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0828-E


Memory became insufficient during execution of JP1/IM - View.

JP1/IM - View could not start because a memory shortage occurred.

S:
Terminates processing.

O:
Allocate sufficient memory to start JP1/IM - View, and then restart JP1/IM - View.

KAVB0830-E


An invalid logical host name (logical-host-name) is specified.

The specified logical host name is invalid.

S:
Terminates processing.

O:
Specify the correct logical host name, and then retry the operation.

KAVB0831-E


JP1/IM - Manager has started.

The command cannot be executed because JP1/IM - Manager is running.

S:
Terminates processing.

O:
Stop JP1/IM - Manager, and then retry the operation.

KAVB0832-E


Common definition information setting has failed.

An attempt to set common definition information failed.

S:
Terminates processing.

O:
Retry the operation. If an error still occurs, use the data collection tool to collect data, and then contact a system administrator.

KAVB0833-E


An attempt to read the event acquisition settings in the system profile has failed.

The event acquisition condition settings in the system profile could not be read because of the following reason(s).

  • Another application is using the .system file.
  • Unable to read the .system file.
  • The contents of the .system.conf file are corrupted.

S:
Terminates processing.

O:
Check the following items, and then retry the operation.
  • Is another application using the .system file?
  • Can the .system file be read?
If the reason for the error is neither of the above, the contents of the .system.conf file may be corrupted. Overwrite the .system.conf file with the .system.conf.model file to return the setting information to its initial status, and then reconfigure the system environment.

KAVB0834-E


An attempt to move the event acquisition filter has failed.

The event acquisition filter could not be moved because of the following reason(s).

  • Another application is using the receive_filter.conf file.
  • Unable to write to the receive_filter.conf file.
  • Insufficient disk space.

S:
Terminates processing.

O:
Check the following items, and then retry the operation.
  • Is another application using the receive_filter.conf file?
  • Can the receive_filter.conf file be written to?
  • Is there sufficient disk space to move the event acquisition filter?

KAVB0835-E


Only one jcochafmode command can be executed at one time.

The jcochafmode command is being executed.

S:
Terminates processing.

O:
After processing of the current jcochafmode command is complete, retry the operation.

KAVB0836-I


The event acquisition filter was switched from interchangeability to the ordinary mode.

The event acquisition filter was switched from compatible mode to ordinary mode.

S:
Continues processing.

KAVB0837-E


The start of JP1/IM - Manager was not able to be confirmed. Please confirm whether JP1/IM - Manager has stopped and execute the command again.

Startup of JP1/IM - Manager could not be confirmed.

S:
Terminates processing.

O:
Use the jco_spmd_status command to determine whether JP1/IM - Manager has stopped, and then retry the operation.
If you specified a logical host, make sure that the shared disk of the logical host has been mounted.

KAVB0838-E


The settings for common definition information are incorrect. Key:(key-value) param:(acquired-value)

The values set for common definition information are invalid.

S:
Terminates processing.

O:
Retrieve the file corresponding to key-value from the backup file, and use the jbssetcnf command to reset the common definition.

KAVB0839-E


Failed to read common definition information. Key:(key-value)

An attempt to read common definition information failed.

S:
Terminates processing.

O:
Retrieve the file corresponding to key-value from the backup file, and use the jbssetcnf command to reset the common definition.

KAVB0840-E


A system error occurred while executing the command (command-name).
Details:(detailed-information)

A system error occurred while executing the command.

S:
Terminates processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0841-E


No executing permission.

There is no permission to execute the command.

S:
Terminates processing.

O:
Log in again as an administrator who has execution permission, and then retry the operation.

KAVB0842-E


Setting information in the system profile is invalid.
Details:(detailed-code)

Setting information in the system profile is invalid.

S:
Terminates processing.

O:
Overwrite the .system file with the .system.model file to return the setting information to its initial status, and then reconfigure the system environment.

KAVB0851-E


JP1/IM - Manager is not running.

Switching cannot be executed because JP1/IM - Manager is not running.

S:
Terminates processing.

O:
Make sure that JP1/IM - Manager is running, and then retry the operation.

KAVB0852-E


The startup status of JP1/IM - Manager could not be checked.

Switching cannot be executed because the running status of JP1/IM - Manager cannot be confirmed.

S:
Terminates processing.

O:
Make sure that JP1/IM - Manager is running, and then retry the operation.

KAVB0853-E


The event acquisition filter is operating in a compatible mode

Switching cannot be executed because the event acquisition filter is operating in compatible mode.

S:
Terminates processing.

O:
Check the event acquisition filter mode, and then retry the operation.

KAVB0854-E


The specified filter does not exist.(filterID: filter-ID)

Switching cannot be executed because a filter condition with the filter ID specified by the argument does not exist.

S:
Terminates processing.

O:
Display the list of event acquisition filters, make sure the filter with the specified ID exists, and then retry the operation.

KAVB0855-I


The aquisition filter in hostname will now be switched.(filterID: filter-ID)

Indicates that switching of the event acquisition filter will start.

S:
Continues processing.

KAVB0856-I


The list of event acquisition filters will now be displayed. (host name: host-name)

Display of the event acquisition filter list will start.

S:
Continues processing.

KAVB0857-I


A connection to JP1/IM - Manager has been established.

JP1/IM - Manager was connected.

S:
Continues processing.

KAVB0858-I


The event acquisition filter was switched successfully.

Switching of the event acquisition filter finished normally.

S:
Continues processing.

KAVB0859-E


An attempt to switch the event acquisition filter has failed. (service = control)

An attempt to switch the event acquisition filter for the displayed control failed.

S:
Continues switching processing of the event acquisition filter for other controls.

O:
Determine whether the displayed control is running. If the displayed control is running, check the integrated trace log to see if an error message was output. If an error message was output, take the corrective action given for that message. If no message was output, use the data collection tool to collect data, and then contact a system administrator.

KAVB0860-I


Switching of the event acquisition filter was successful. (service = control)

The event acquisition filter for the displayed control was switched.

KAVB0861-I


Switching of the event acquisition filter has finished.

Switching of the event acquisition filter is complete.

KAVB0862-E


An attempt to switch the event acquisition filter has failed.

An attempt to switch the event acquisition filter failed.

S:
Aborts processing to switch the event acquisition filter.

O:
Determine whether the displayed control is running. If the displayed control is running, check the integrated trace log to see if an error message was output. If an error message was output, take the corrective action given for that message. If no message was output, use the data collection tool to collect data, and then contact a system administrator.

KAVB0863-E


The specified common exclusion condition does not exist. (common exclusion condition ID = common-exclusion-conditions-group-ID)

Switching cannot be executed because common exclusion conditions with the common exclusion conditions group ID specified by the argument do not exist.

S:
Terminates processing.

O:
Display the list of event acquisition filters and the list of common exclusion conditions, make sure that the common exclusion conditions of the specified ID exist, and then retry the operation.

KAVB0864-I


The common exclusion condition will now be enabled. (common exclusion condition ID = common-exclusion-conditions-group-ID[,common-exclusion-conditions-group-ID...])

A common exclusion condition is enabled.

S:
Continues processing.

KAVB0866-E


A common exclusion condition ID is duplicated.

The specified common exclusion conditions group ID is duplicated.

S:
Terminates processing.

O:
Carefully review the specification.

KAVB0868-I


All common exclusion conditions will now be enabled.

All specified common exclusion conditions group IDs are enabled.

S:
Continues processing.

KAVB0869-I


All common exclusion conditions will now be disabled.

All specified common exclusion conditions group IDs are disabled.

S:
Continues processing.

KAVB0870-E


The common exclusion conditions could not be set because the maximum length of the event acquisition filter (65536 bytes) was exceeded.

The event acquisition filter exceeds the maximum length that can be specified.

S:
Terminates processing.

O:
Reduce the event acquisition filter or common exclusion condition to a length no greater than the maximum.

KAVB0871-E


The common exclusion condition does not exist.

Processing to switch between enabling and disabling of a common exclusion condition is terminated because the common exclusion condition does not exist.

S:
Terminates processing.

O:
Display a list of common exclusion conditions, make sure that the common exclusion condition exists, and then retry the operation.

KAVB0872-E


The JP1/Base instance on the manager host does not support the common exclusion condition.

The common exclusion condition is not supported because the JP1/Base on the manager host is not version 08-50 or later.

S:
Terminates processing.

O:
Check the version of the JP1/Base on the manager host. To set common exclusion conditions, version 08-50 or later of JP1/Base must have been installed.

KAVB0873-E


Information about the event cannot be output because the IM Database service is not running.

The event cannot be acquired because the integrated monitoring database is not running.

S:
Terminates processing.

O:
Start the integrated monitoring database, and then retry the operation.

KAVB0874-E


Information about the event cannot be output because the Integrated Monitoring Database has not been set up.

The event to be output does not exist because the integrated monitoring database has not been set up.

S:
Terminates processing.

O:
Set up the integrated monitoring database, and then retry the operation.

KAVB0875-E


The file-type file file-name does not exist.

The specified file does not exist.

S:
Terminates processing.

O:
Make sure the specified file name is correct, and then retry the operation.

KAVB0876-E


An attempt to read the file-type file file-name has failed.

An I/O error occurred during reading of the file.

S:
Terminates processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB0877-E


The syntax of an item file is invalid. reason (line = line-number, file name = file-name)

There is an error in the contents of the item file.

S:
Terminates processing.

O:
Identify the cause based on the invalid contents, carefully review the item file, and then retry the operation.

KAVB0878-E


The syntax of a filter file is invalid. reason (line = line-number, file name = file-name)

There is an error in the contents of the filter.

S:
Terminates processing.

O:
Identify the cause based on the invalid contents, carefully review the filter, and then retry the operation.

KAVB0879-E


The format specified for specification-item is invalid.

The entered date and time is not specified as numeric characters in YYYYMMDDhhmmss format.

S:
Terminates processing.

O:
Carefully review the entered date and time, and then retry the operation.

KAVB0880-E


The value specified for specification-item is outside the valid range.

The entered date and time is before 1970/01/01 00:00:00 or after 2038/01/19 03:14:07.

S:
Terminates processing.

O:
Carefully review the entered date and time, and then retry the operation.

KAVB0881-E


The value specified for specification-item is not valid date and time information.

The entered date and time does not exist.

S:
Terminates processing.

O:
Carefully review the entered date and time, and then retry the operation.

KAVB0882-I


Number-of-output-events events were successfully output in the function-name.

Output of event reports was successful.

S:
Terminates processing.

KAVB0883-E


The funtion-name failed. (detailed information = detailed-information)

An attempt to output the event report failed.

S:
Terminates processing.

O:
Take the corrective action given for the detailed information in the error message that was displayed after executing the command.

detailed-information
4: File I/O error
101: The integrated monitoring database is not set up.
102: The IM database service is not running.
103: An error occurred in connecting to the IM database service.
254: Memory shortage
255: System error

KAVB0884-E


Multiple instances of the jcoevtreport command cannot be executed at the same time.

More than one jcoevtreport command cannot be executed at the same time.

S:
Terminates processing.

O:
Wait until processing of the current jcoevtreport command is complete, and then retry the jcoevtreport command.

KAVB0885-E


The file cannot be saved because the file name is too long. (file = file-name)

A file name using an absolute path exceeds 250 characters.

S:
Terminates processing.

O:
Correct the file name in an absolute path so that it is no more than 250 characters, and then retry the operation.

KAVB0886-E


The serial number of the output file reached the maximum value.

The serial number of the output file reached the maximum value.

S:
Terminates processing.

O:
Change the output file name, and then retry the operation.

KAVB0887-E


The size of the file-type file exceeds the upper limit. (file name = file-name, upper limit = upper-limit)

The size of the specified file exceeds the maximum value.

S:
Terminates processing without reading the specified file.

O:
Carefully review the contents of the file to see if it contains extra comments or redundant definitions, and correct the file so that its size is no greater than the maximum value. After correcting the file, retry the operation.

KAVB1002-I


The command (command-name) terminates normally.

The command ended normally.

KAVB1003-I


The command (command-name) terminates abnormally.

The command ended abnormally.

KAVB1004-E


System error occurred in executing the command (command-name).

A system error occurred while executing the command.

S:
Stops command execution.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1005-I


The command (command-name) has started.

The command has started.

KAVB1010-E


Extra arguments (identifier) are specified.

Extra arguments are specified for the command.

S:
Stops command execution.

O:
Determine the correct use of the command, and then enter the command again.

KAVB1011-E


Arguments are missing.

Arguments specified for the command are missing.

S:
Stops command execution.

O:
Determine the correct use of the command, and then enter the command again.

KAVB1101-E


System error occurred in analyzing the definition file.

A system error occurred during analysis of the definition file.

S:
Stops analysis of the definition file.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1102-E


Memory shortage occurred in analyzing the definition file.

A memory shortage occurred during analysis of the definition file.

S:
Stops analysis of the definition file.

O:
Allocate sufficient memory for command execution, and then re-execute analysis processing.

KAVB1111-E


An I/O error occurred in analyzing the file (file-name).

An I/O error occurred during analysis of the definition file.

S:
Stops analysis of the definition file or analysis of the file where the I/O error occurred and continues processing.

O:
Make sure the value in the encode file is correctly set, or use the data collection tool to collect data, and then contact a system administrator.

KAVB1112-E


Cannot access the directory (directory-name).

The directory does not exist, or a file name is specified. Another possibility is that there is no access permission for the directory.

S:
Stops analysis of the directory.

O:
Specify the directory correctly.

KAVB1113-W


Cannot access the file (file-name).

The file does not exist, or a directory name is specified. Another possibility is that there is no access permission for the file.

S:
Stops analysis of the file specified by file-name and continues processing other files.

O:
Specify the file correctly.

KAVB1114-W


The block is constructed incorrectly. processing-contents, Cause cause-information (file-name:line-number)

processing-contents is executed because the block in the definition file is constructed incorrectly.

S:
Stops analysis of the specified file and continues processing other files.

O:
Construct the block correctly according to cause-information.

KAVB1115-W


The record is constructed incorrectly. processing-contents, Cause cause-information (file-name:line-number)

processing-contents is executed because the record in the definition file is constructed incorrectly.

S:
Executes processing-contents and continues processing.

O:
Construct the record correctly according to cause-information.

KAVB1116-W


Mandatory parameters(identifier) are not specified. processing-contents, (file-name:line-number)

processing-contents is executed because the required parameters are not specified in the definition file or a record in the definition file.

S:
Executes processing-contents and continues processing.

O:
Specify the missing parameters.
However, if a message is output because the linkage product is not installed, corrective action is not necessary.

KAVB1117-W


Extra parameters (identifier) are specified. processing-contents:(file-name:line-number)

Processing indicated in processing-contents is executed because extra parameters are specified in the definition file or a record in the definition file.

S:
Executes processing-contents and continues processing.

O:
Delete extra parameters.

KAVB1118-W


Undefined parameters(identifier) are specified. processing-contents:(file-name:line-number)

Processing indicated in processing-contents is executed because undefined parameters are specified in the definition file or a record in the definition file.

S:
Executes processing-contents and continues processing.

O:
Check the version of JP1/IM - Manager and define parameters using the contents supported by the version.

KAVB1119-W


Invalid value (identifier) is specified. processing-contents:(file-name:line-number)

Processing indicated in processing-contents is executed because invalid values are specified in the definition file or a record in the definition file.

S:
Executes processing-contents and continues processing.

O:
Define correct values.

KAVB1120-W


The value(identifier) is duplicated. processing-contents (file-name:line-number)

Processing indicated in processing-contents is executed because a value that is already defined is specified in the definition file or a record in the definition file.

S:
Executes processing-contents and continues processing.

O:
Change the value that is already defined or the current definition.

KAVB1121-W


"identifier-1" and "identifier-2" cannot be specified at the same time. processing-contents: (file-name:line-number)

Processing indicated in processing-contents is executed because values that cannot be specified at the same time are specified in the definition file or a record in the definition file.

S:
Executes processing-contents and continues processing.

O:
Delete identifier-1 or identifier-2.

KAVB1130-W


An attempt to read the file that defines which items are displayed for event conditions has failed. (file: file-name)

An attempt to read the file that defines which items are displayed for event conditions failed.

S:
Stops reading the file and continues processing.

O:
Check the following OS log items to see if a shortage has occurred in OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: System log (syslog)
If a resource shortage has not occurred, use the data collection tool to collect data, and then contact a system administrator.

KAVB1131-W


The display item is not specified. (file = file-name)

The default value is specified because the display item is not specified in the file that defines which items are displayed for event conditions.

S:
Uses the default value to continue processing.

O:
Specify the display item in the file that defines which items are displayed for event conditions, and then restart or reload Central Console.

KAVB1132-W


More than 256 display item have been specified. (line = line-number, file = file-name)

More than 256 display items are specified in the file that defines which items are displayed for event conditions.

S:
Stops reading data and continues processing. Ignores display items after 256 items.

O:
Correct the file that defines which items are displayed for event conditions, and then restart or reload Central Console.

KAVB1133-W


The display item has been duplicated. (line = line-number, file = file-name)

The display item specified in the file that defines which items are displayed for event conditions is duplicated.

S:
Ignores the line where the item is duplicated and continues processing.

O:
Correct the file that defines which items are displayed for event conditions, and then restart or reload Central Console.

KAVB1134-W


An invalid display item is specified. (line = line-number, file = file-name)

An invalid display item is specified in the file that defines which items are displayed for event conditions.

S:
Ignores the line where the invalid item is specified and continues processing.

O:
Correct the file that defines which items are displayed for event conditions, and then restart or reload Central Console.

KAVB1135-E


The file that defines which items are displayed for event conditions was not found.

The file that defines which items are displayed for event conditions was not found.

S:
Stops reading of the file that defines which items are displayed for event conditions and continues processing.

O:
Check the following items, and then restart JP1/IM - Manager or execute the jco_spmd_reload command.
  • Determine whether the file that defines which items are displayed for event conditions exists. If the file does not exist, create the file.
  • Determine whether there is read permission for the file that defines which items are displayed for event conditions. If there is no read permission, set read permission for the file that defines which items are displayed for event conditions.

KAVB1200-E


Communication error occurred in establishing the connection.
Host name: host-name, Port number: port-number
Details: detailed-information

An attempt to connect to the specified host failed.

S:
Suspends processing.

O:
Check the following items, and then retry the operation.
  • Is the entered connecting host name correct?
  • Is the host to be connected running?
  • Is there a communication problem with the host to be connected to?

KAVB1201-E


Communication error occurred in receiving data.
Host name: host-name, Port number: port-number
Details: detailed-information

Reception processing failed during communication.

S:
Suspends processing.

O:
Perform the operation again.

KAVB1202-E


Communication error occurred in sending data.
Host name: host-name, Port number: port-number
Details: detailed-information

Send processing failed during communication.

S:
Suspends processing.

O:
Perform the operation again.

KAVB1203-E


Communication error occurred during communication.
Host name: host-name, Port number: port-number
Details: detailed-information

An error occurred during communication.

S:
Suspends processing.

O:
Perform the operation again.

KAVB1204-E


An error occurred in the communication processing.
Host name: host-name, Port number: port-number
Details: detailed-information

An error occurred during communication processing at the viewer side.

S:
Suspends processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1205-E


Timeout occurred in the server processing.
Host name: host-name, Port number: port-number

A time-out occurred during processing at the server side.

S:
Suspends processing.

O:
Carefully review the communication time-out setting.

KAVB1206-E


An error occurred in starting the server.
Host name: host-name, Port number: port-number
Details: detailed-information

An attempt to start the server failed.

S:
Suspends processing.

O:
Contact a network administrator.

KAVB1207-E


An error occurred in the communication processing on the server side.
Host name: host-name, Port number: port-number
Details: detailed-information

An error occurred during communication processing at the server side.

If you are using an integrated monitoring database, the integrated monitoring database is not in operating status.

S:
Suspends processing.

O:
  • When this message is displayed while using the jcochstat command:
    You cannot use the jcochstat command with JP1/IM - Central Console (Satellite Console) version 06-00. Check the version of the specified JP1/IM - Central Console (Satellite Console).
  • When an integrated monitoring database is used:
    Execute the jimdbstatus command to check the status of the IM database service of the manager host. If you are able to confirm that the IM database service is operating, retry the operation. If a KAVB8602-E message was output in the integrated trace log of the manager host, take the corrective action given for that message.
  • In cases other than the above:
    Use the data collection tool to collect data, and then contact a system administrator.

KAVB1208-E


An error occurred in communication processing.
Details:detailed-information

An error occurred during communication processing at the server side.

S:
Suspends processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1209-E


An error occurred in the server side communication processing.
Details:detailed-information

An error occurred during communication processing at the server side.

S:
Suspends processing.

O:
  • When this message is displayed during login to JP1/IM - Console View version 06-51:
    JP1/IM - Console View version 06-51 cannot be connected to JP1/IM - Central Console (Satellite Console) version 06-00. Check the version of the specified JP1/IM - Central Console (Satellite Console).
  • In cases other than the above:
    Use the data collection tool to collect data, and then contact a system administrator.

KAVB1210-E


A communication error occurred while establishing a connection.
Cannot convert the host name into an IP address.
Confirm the host name.
Host name:host-name, Port number:port-number
Details:detailed-information

A communication error occurred while establishing a connection.

S:
Continues processing.

O:
If you are using the system in a DNS environment, check the DNS settings.
If you are using the system using the hosts file, check the hosts file settings.

KAVB1211-W


The port number of the service-name service could not be acquired.
The default port number port-number will be used now and the system will run.
Confirm the setting.

An attempt to acquire the port number failed while starting JP1/IM - Manager.

S:
Uses the default port number and continues processing.

O:
Carefully review the port number setting.

KAVB1401-E


Failed to build a message due to an exception (exception-class-name).

An attempt to build a message failed because an exception occurred.

S:
Suspends processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1402-W


Failed in the output of a log file. (file-name)

An attempt to output a log file failed due to a cause such as frequent disk I/O.

S:
Continues processing. Outputs the log file again.

O:
When you output log files in succession, make sure that there is sufficient capacity on the disk where the log files are stored. If disk space is insufficient, allocate sufficient disk space to store the log files.

KAVB1403-W


Deleted the log which failed to output to a log file. (file-name)

The log for which output to a log file failed was deleted.

S:
Continues processing.

O:
Make sure that there is sufficient capacity on the disk where the log files are stored. If disk space is insufficient, allocate sufficient disk space to store the log files.

KAVB1501-E


Cannot execute the request. Invalid data is included in the request to the server.
Server name=server-name
Request to server=request-to-server

Invalid information is included in the request to the server.

S:
Suspends processing.

O:
Retry the operation. If the same message is displayed, collect data, and then contact a system administrator.

KAVB1502-E


System error occurred in the server.
Server name=server-name

A system error occurred.

S:
Suspends processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1503-E


Memory shortage occurred in the server.
Server name=server-name

A memory shortage occurred in the server.

S:
Suspends processing.

O:
In the unit at the manager side, exit applications that are not being used.

KAVB1504-E


An error occurred in the communication between the server and Event Service.
Server name=server-name

The possible causes are as follows:

  • The manager is not running.
  • Event Service is not running.
  • The processing request load is temporarily high.

S:
Suspends processing.

O:
Take corrective action according to the cause of the error.
  • Make sure that the manager is running.
  • Make sure that Event Service is running.
  • Retry the operation. If repeated retrying does not work, restart the viewer, and then retry the operation.

KAVB1506-E


Cannot find the file in the server.
Server name=server-name
File name=file-name

An error occurred in the manager.

S:
Suspends processing.

O:
Contact a system administrator.

KAVB1507-E


The object on the server is not in the state to be able to accept the request.
Server name=server-name
Object=object
Status=status
Request=request

The object on the server is not in a state able to accept the request.

S:
Suspends processing.

O:
Wait awhile, and then retry the operation.

KAVB1509-E


Failed to communicate with the server.
Server name=server-name

The possible causes are as follows:

  • The manager is not running.
  • Event Service is not running.
  • The processing request load is temporarily high.
  • The IM database service is not in operating status.

S:
Suspends processing.

O:
Take corrective action according to the cause of the error.
  • Make sure that the manager is running.
  • Make sure that Event Service is running.
  • Retry the operation. If repeated retrying does not work, restart the viewer, and then retry the operation.
  • If you are using an integrated monitoring database, execute the jimdbstatus command to check the status of the IM database service of the manager host. If you are able to confirm that the IM database service is operating, retry the operation. If a KAVB8602-E message was output in the integrated trace log of the manager host, take the corrective action given for that message.

KAVB1510-E


Failure either in the file or network I/O on the server.
Server name=server-name

An error occurred in the manager.

S:
Suspends processing.

O:
Check the integrated trace log of the manager to see if an Event Console Service error message was output (error messages KAVB0001 to KAVB2000).
If a message was output, take the corrective action given for that message.
If the problem cannot be resolved, check the following OS log items to see if a shortage has occurred in OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: System log (syslog)
If a resource shortage has not occurred, use the data collection tool to collect data, and then contact a system administrator.

KAVB1512-E


System error occurred.

A system error occurred.

S:
Suspends processing.

O:
Contact a system administrator.

KAVB1513-W


Cannot display some event(S).
There were no events to obtain from the event buffer on the connecting host.
All the events except the above will be displayed.
To search for an event which was not displayed, specify the search conditions
in the event search condition settings dialog as follows:
(1) In "Search host", specify the name of the connecting host.
(2) In "Registered timeframe", specify the times when the events before and after this event were registered.
Check to see if the following conditions are met when this event appears frequently.
(1) The "Interval" value that was set for "Automatic refresh" in the Preferences window is too long.
(2) The "Num. of events to acquire at update" value that was set in the Preferences window is too small.
(3) The "Event buffer" value for the Manager that was set in the System Environment Settings window is too small.

The event could not be displayed because the event (including hidden events) that the system tried to acquire was not in the event buffer of the connected host.

S:
Continues processing.

O:
If this message is displayed frequently, carefully review the settings to see if any of the following conditions apply.
  • The Interval setting for Automatic refresh specified in the Preferences window is too long.
  • The Num. of events to acquire at update setting specified in the Preferences window is too small.
  • The Event buffer setting of the manager specified in the Preferences window is too small.

KAVB1515-E


Failed to obtain the information about the event selected. Cannot continue processing.

The selected information could not be obtained from Event Service.

S:
Suspends processing.

O:
  • Check the contents of the selected event, the position in the scroll buffer, and whether Event Service is running. Also, make sure that the selected event is on the event database.
  • If you are using an integrated monitoring database, determine whether any of the following messages is displayed in the integrated trace log of the manager. If a message is output, take the corrective action given for that message.
    [Figure] KAVB1660-E
    [Figure] KAVB1661-E
    [Figure] KAVB1662-E
    [Figure] KAVB1678-E
    If no message is output, contact a system administrator.

KAVB1516-W


An error occurred in acquiring an event from the event service.
Cannot recover the error after attempting the number of retries specified in the system profile.
No more events will be displayed from now on due to this error. Please check if the event service is running or not.
If not, recover the error by re-executing the manager after starting the event service.

An error occurred while acquiring an event from Event Service.

S:
Continues processing.

O:
Determine whether Event Service is running.
If Event Service is not running, start Event Service, and then start the manager to recover from the error.
If this message appears in the Search Events page of the Event Console window after event search is executed, confirm that the search host name is correct.
Make sure that the address of the connecting host name and search host name can be resolved on the manager.

KAVB1517-I


Started the manager.

The manager was started.

KAVB1518-I


Stopped the manager.

The manager was stopped.

KAVB1519-I


Stopping the manager because a termination request was received.

The manager was stopped because a termination request was received.

KAVB1520-E


Stopping the manager because an interruption.
Details:detailed-information

An error occurred in the manager.

S:
Stops the manager.

O:
Contact a system administrator.

KAVB1521-E


Stopping the manager because an error occurred.
Details:detailed-information

An error occurred in the manager.

S:
Stops the manager.

O:
Contact a system administrator.

KAVB1522-E


JP1/Base Event Service could not be connected so no further events will be displayed.

Connection between the manager and Event Service cannot be established.

O:
Determine whether Event Service is running.
If Event Service is not running, start Event Service, and then start the manager to recover from the error.
If this message is output after event search is executed, confirm that the search host name is correct.

KAVB1523-E


Some of the events selected no longer exist in the event DB on the Manager host.
So, their event attributes have not been changed.

An attempt was made to change the action status of an event or to delete an event that does not exist in the event database. Therefore, the event attributes could not be updated. This occurs when a new event exceeds the capacity of the event database on the manager, or when the event database is deleted.

S:
Refreshes the display on the active event console and continues processing.

KAVB1524-E


Could not apply the changes in the selected JP1 event attributes to the event DB on the Manager host.

An attempt to communicate with Event Service of JP1/Base failed.

S:
Continues processing.

O:
  • Make sure that Event Service of JP1/Base is running. If it is not running, start Event Service, and then perform the operation again.
  • If you are using an integrated monitoring database, check the integrated trace log of the manager to see if any of the following messages is displayed. If a message is output, take the corrective action given for that message.
    [Figure] KAVB1663-E
    [Figure] KAVB1664-E
    [Figure] KAVB1665-E
    [Figure] KAVB1674-E
    [Figure] KAVB1675-E
    [Figure] KAVB1676-E
    If no message is output, contact a system administrator.

KAVB1525-E


An internal definition file is invalid. (detailed-information)

The definition information in the internal definition file is incorrect.

S:
Terminates processing of JP1/IM - Manager and JP1/IM - View. Also terminates the jcochstat command processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1526-E


The specified event cannot change the corresponding conditions. Confirm the specified number of the serial number in the event DB.

A serial number in the event database of an event that cannot be updated is specified.

S:
Terminates processing.

O:
Carefully review the specified serial number in the event database.

KAVB1527-E


A condition that cannot be received by the search host is included.

Event search was executed by specifying either of the following, which are not supported by Event Service version 06-00 or earlier.

  • Is contained or Is not contained is specified.
  • More than one action status is specified.

Another possibility is that a regular expression that is not supported by Event Service version 06-00 or earlier is specified.

S:
Closes the Event Search Conditions window and returns to the Event Console window.

O:
  • Specify Match, Does not match, or First characters, and then retry the search.
  • Specify only one action status, and then retry the operation.

KAVB1528-E


The specified value of a definition setting is out of range. (setting item:setting)

The setting is out of range.

S:
Operates by rounding up the setting.

O:
Carefully review the setting.

KAVB1529-E


The value of a common definition setting is out of range. (label:setting)

The setting is out of range.

S:
Ignores the setting and continues processing using the default value.

O:
Carefully review the setting.

KAVB1531-E


definition-file is corrupt.
filename: file-name

An attempt to read the definition file failed because the definition file is corrupted.

S:
Terminates processing.

O:
Restore the definition file from the backup of the definition file displayed for file-name, and then restart JP1/IM - Manager. If the definition file has not been backed up, perform the following for each definition file.
  • For an event acquisition filter definition file, use the following method to copy the event acquisition definition file. After that, restart JP1/IM - Manager and reconfigure the event acquisition filter definition.
    In Windows:
    copy Console_path\conf\console\filter\receive_filter.conf.model Console_path\conf\console\filter\receive_filter.conf
    In UNIX:
    cp -p /etc/opt/jp1cons/conf/console/filter/receive_filter.conf.model /etc/opt/jp1cons/conf/console/filter/receive_filter.conf
  • For other definition files, delete the definition file, and then restart JP1/IM - Manager.

KAVB1532-E


The specified value of a definition setting is out of range.(setting item:setting)

The setting is outside the specifiable range.

S:
Ignores the setting and continues processing using the default value.

O:
Carefully review the setting.

KAVB1551-E


An attempt to save the event-information mapping definition failed.

An attempt to write to the mapping definition file failed.

S:
Stops saving the mapping definitions and continues processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1552-E


An attempt to read the event-information mapping definition failed.

An attempt to read the mapping definition file failed.

S:
Uses the default mapping definitions and continues processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1554-E


A nonnumeric attribute value (attribute-value) cannot be mapped to a time-related display item (attribute-name).

For a time-related display item, a non-numeric value (number of seconds from UTC 01/01/1970 0:00:00) is specified.

S:
Ignores this time-related display item and continues mapping processing.

O:
For a time-related display item, specify numeric values (0 to 2,147,483,647 = UTC 01/01/1970 00:00:00 to 01/19/2038 3:14:07).

KAVB1556-E


During mapping of event information, a system error occurred.

An unexpected error was detected during mapping processing.

S:
Terminates processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1558-E


An attempt to update the notification status has failed. (function ID = ID, detailed code = code)

An attempt to update notification status failed.

S:
Suspends update processing of notification status.

O:
If the same message appears repeatedly, collect data, and then contact a system administrator.

KAVB1570-I


A connection request from JP1/IM - View was refused because startup of the IM database service has not finished yet.

A connection request from JP/IM - View was rejected because the system is waiting for startup of the IM database service to finish.

S:
Continues processing.

KAVB1571-I


A connection request from JP1/IM-Console View V6 (6i) was refused.

Connection was rejected because the setting to reject connection requests from JP1/IM - Console View V6 (6i) took effect.

KAVB1572-I


A connection request from jcochstat was refused.

Connection was rejected because the setting to reject connection requests from the jcochstat command took effect.

KAVB1573-W


The filter setting from JP1/IM - View was discarded, because an event receiver filter that uses OR is specified in JP1/IM - Manager.

The user filter setting from JP1/IM - View version 07-00 or earlier was discarded because a user filter using OR is set in JP1/IM - Manager.

S:
Invalidates the user filter setting and continues processing.

O:
To specified a user filter for JP1/IM - Manager in which a user filter using OR is set, use JP1/IM - View version 08-01 or later.

KAVB1574-W


The event acquisition settings in the system environment settings were discarded, because the version of JP1/IM - View currently in use is version 07-00 or earlier.

The event acquisition settings in the system environment settings are invalid because the version of JP1/IM - View being used is 07-00 or earlier. The event acquisition settings cannot be referenced or used.

S:
Ignores the event acquisition settings and continues processing.

O:
To set an event acquisition filter, use JP1/IM - View version 08-01 or later.

KAVB1575-W


The filter setting from JP1/IM - View was discarded, because a severe event definitions that uses OR is specified in JP1/IM - Manager.

The severe event setting from JP1/IM - View version 07-00 or earlier was discarded because severe event definitions using OR are set in JP1/IM - Manager.

S:
Invalidates the severe event definition setting and continues processing.

O:
To set a severe event definition in JP1/IM - Manager where a severe event definition using OR is set, use JP1/IM - View version 08-01 or later.

KAVB1576-E


The filtering process for severe event definitions has failed. (Serial number: serial-number-in-event-database, Event ID: event-ID)

An attempt to perform filtering process for severe event definitions failed because the severe event definitions could not be acquired. The event for which filtering process for severe event definitions failed is not displayed in the Severe Events page of the Event Console window even though it matches the severe event definitions.

S:
Continues processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1577-I


A status operation was performed. (user who performed the operation = JP1-user, event ID = event-ID, status before operation = status-before-operation, status after operation = status-after-operation)

The action status operation was performed.

S:
Continues processing.

KAVB1578-E


An attempt to read the status event definition file (processupdate.conf) has failed. The default value will be used. (reason = reason)

An attempt to read the status event definition file (processupdate.conf) failed. The default value Do not issue the status event (00003F11) is used to continue processing.

S:
Assumes the default value Do not issue the status event (00003F11) and continues processing.

O:
  • When The file does not exist. is displayed for the reason:
    Use the processupdate.conf name to copy the model file (processupdate.conf.model) of the status event definition file, change definitions as necessary, and then restart JP1/IM - Manager.
    If the file exists, make sure that the access permission is correctly set, and then restart JP1/IM - Manager.
  • When A file I/O error occurred. is displayed for the reason:
    Use the data collection tool to collect data, and then contact a system administrator.
  • When a reason other than the above is displayed:
    Use the data collection tool to collect data, and then contact a system administrator.

KAVB1579-E


There is an error in the status event definition file (processupdate.conf). The default value will be used. (line line-number = detailed-information)

Because an invalid value is set in the status event definition file (processupdate.conf), the default value Do not issue the status event (00003F11) is used to continue processing.

S:
Assumes the default value Do not issue the status event (00003F11) and continues processing.

O:
Make sure that the definition file is correctly set, and then restart JP1/IM - Manager.

KAVB1580-I


A JP1 event (event-ID) was issued.

A JP1 event was issued.

S:
Continues processing.

KAVB1581-E


Information necessary for the status event (event-ID) could not be acquired from the event DB. (reason = reason)

The status event (00003F11) could not be issued because information required for the status event could not be retrieved from the event database.

S:
Continues processing.

O:
Determine whether JP1/Base Event Service is running. If it is not running, start the service.
If JP1/Base Event Service is running, use the data collection tool to collect data, and then contact a system administrator.

KAVB1582-E


A JP1 event (event-ID) could not be issued. (reason = reason)

A JP1 event could not be issued.

S:
Stops issuing the JP1 event.

O:
Determine whether JP1/Base Event Service is running. If it is not running, start the service.
If JP1/Base Event Service is running, use the data collection tool to collect data, and then contact a system administrator.

KAVB1583-W


The filter setting (filter) from JP1/IM - View was discarded because the filter setting (filter) that uses the exclusion condition is specified in JP1/IM - Manager.

The setting from JP1/IM - View was discarded because a filter that uses the exclusion condition is specified in JP1/IM - Manager.

S:
Invalidates the setting from JP1/IM - View and continues processing.

O:
To use a filter in JP1/IM -Manager in which the exclusion condition is specified, use JP1/IM - View version 08-50 or later.

KAVB1584-W


The setting of the event acquisition filter from JP1/IM - View was discarded because the event acquisition filter setting that uses the common exclusion condition is specified in JP1/IM - Manager.

The setting from JP1/IM - View was discarded because a filter that uses the common exclusion condition is specified in JP1/IM - Manager.

S:
Invalidates the setting from JP1/IM - View and continues processing.

O:
To use a filter in JP1/IM - Manager in which the common exclusion condition is specified, use JP1/IM - View version 08-50 or later.

KAVB1585-I


Reading of the guide information file has finished. (file-name)
Number of guide information items: number-of-guide-information-items

The event guide information for number-of-guide-information-items was read from the event guide information file (file-name).

S:
Continues processing.

KAVB1586-W


An error occurred while reading a guide information file. (file-name)
Line: line-number
Guide information: tag-name
Details: reason-code

There is an error in the description in the event guide information file or event guide message file.

S:
Continues processing.

O:
According to the following reason codes, correct the description error (line-number) of the file name, and then restart or reload (execute the jco_spmd_reload command) JP1/IM - Manager.
  • Reason code: 000
    Description: Other error
    Corrective action: Contact a system administrator.
  • Reason code: 001
    Description: Unsupported syntax was found. The description up to END is ignored. The tags are output if tags other than EV_GUIDE_event-guide-number are described.
    Corrective action: Correct the relevant location.
  • Reason code: 002
    Description: Unsupported syntax was found. This line is ignored.
    Corrective action: Correct the relevant location.
  • Reason code: 101
    Description: DESC_VERSION is specified multiple times. This DESC_VERSION is ignored.
    Corrective action: Specify only one DESC_VERSION.
  • Reason code: 201
    Description: The specification of the EV_GUIDE_event-guide-number tag is invalid. The event guide number must be a number between 1 and 9999. This event guide information is ignored.
    Corrective action: Change the event guide number to a number between 1 and 9999.
  • Reason code: 202
    Description: More than one EV_GUIDE_event-guide-number tag exists. This event information is ignored.
    Corrective action: Specify a unique EV_GUIDE_event-guide-number tag in the event guide information file.
  • Reason code: 203
    Description: The number of definitions of the event guide information exceeds the maximum value.
    Corrective action: Set the number of definitions to no more than the maximum value.
  • Reason code: 204
    Description: END is not used. The subsequent event guide information is ignored.
    Corrective action: Use END to close EV_GUIDE_event-guide-number.
  • Reason code: 205
    Description: EV_GUIDE, EV_FILE is not used.
    Corrective action: Use EV_GUIDE, EV_FILE to specify the event guide message.
  • Reason code: 301
    Description: The number of definitions of EV_COMP exceeds the maximum value. This comparison condition is ignored.
    Corrective action: Set the number of definitions to no more than the maximum value.
  • Reason code: 302
    Description: The EV_COMP attribute value is invalid. The attribute-name:attribute-value format is not used.
    Corrective action: Use the attribute-name:attribute-value format for the description.
  • Reason code: 303
    Description: The EV_COMP is not specified. This event guide information is invalidated.
    Corrective action: Specify EV_COMP.
  • Reason code: 304
    Description: The regular expression of the comparison condition is invalid.
    Corrective action: Correct the regular expression of the comparison condition.
  • Reason code: 305
    Description: The attribute name does not begin with B. or E..
    Corrective action: For the attribute name, specify a basic attribute of a JP1 event beginning with B. or an extended attribute of a JP1 event beginning with E..
  • Reason code: 401
    Description: The EV_GUIDE attribute is specified multiple times. This EV_GUIDE attribute is ignored.
    Corrective action: Specify only one EV_GUIDE attribute.
  • Reason code: 402
    Description: The length of the event guide message exceeds the maximum value.
    Corrective action: Reduce the length of the event guide message so that it is no more than the maximum value.
  • Reason code: 403
    Description: Only one $ is described.
    Corrective action: To specify $, describe it as \$.
  • Reason code: 404
    Description: Only one \ is described.
    Corrective action: To specify \, describe it as \\.
  • Reason code: 501
    Description: The EV_FILE attribute is specified multiple times. This EV_FILE attribute is ignored.
    Corrective action: Specify only one EV_FILE attribute.
  • Reason code: 502
    Description: The length of the event guide message file name exceeds the maximum value. This EV_FILE attribute is ignored.
    Corrective action: Reduce the length of the event guide message file name so that it is no more than the maximum value.

KAVB1587-E


An error occurred while reading a guide information file. (file-name)
Details: reason-code

An error occurred while reading an event guide information file or event message file.

S:
Stops reading file-name and continues processing.

O:
According to the following reason codes, check the storage location of file-name or the access permission, and then restart or reload (execute the jco_spmd_reload command) JP1/IM - Manager.
  • Reason code: 000
    Description: Other error
  • Reason code: 001
    Description: Unable to open the file.
  • Reason code: 002
    Description: The file size is larger than the maximum value.
    Corrective action: Reduce the file size so that it is no more than the maximum value.
  • Reason code: 003
    Description: An I/O error occurred.
  • Reason code: 004
    Description: The file version is not supported.
    Corrective action: Specify 1.

KAVB1588-I


There is no matching guide information.

There was no event guide information corresponding to the event.

S:
Continues processing.

O:
To set event guide information corresponding to an event, define the event guide information in the event guide information file.

KAVB1589-E


An attempt to start the default browser has failed.

An attempt to start the default browser failed.

S:
Aborts processing.

O:
Assign a Web browser to the extension (html), and then retry the operation.

KAVB1601-W


The basic definition can not be extended. (file-name:line-number)

The basic definition cannot be extended in an extended attribute definition file.

S:
Invalidates the block and continues processing.

O:
Change the extension flag of the relevant block to false or change the platform name to one other than base.

KAVB1602-W


Import definition is incorrect.
Import source:file-name
Import destination:file-name

There is no import file, or a directory name is specified. Another possibility is that there is no access permission for the import file.

You cannot import the import source file.

S:
Continues processing without importing the file.

O:
Define the correct import file name or change the extension flag of blocks which will not be extended to false.

KAVB1603-W


The attribute(identifier) for the attribute name is not found.
product name : product-name
block type : block-type
block platform : platform-name

The attribute value for the attribute name is not described in the extended attribute definition file.

S:
Invalidates the record and continues processing.

O:
Define the attribute value corresponding to identifier. Also, delete the relevant record.

KAVB1611-W


The table version is not previously defined. processing-contents(file-name:line-number)

processing-contents is executed because the table version is not defined at the beginning of the interface definition file.

S:
Executes processing-contents and continues processing.

O:
Define the table version at the beginning of the definition file.

KAVB1612-W


The number of defined attributes exceeds the limit (maximum-number-of-attribute-name-definitions). The definition after this line will be ignored. (file-name:line-number)

Subsequent definitions are invalidated because the number of attribute definitions exceeds the maximum value in the interface definition file.

S:
Invalidates subsequent records after the maximum number is reached and continues processing.

O:
Delete extra attribute names from the relevant definition file.

KAVB1613-W


No definition for the value(identifier). (file-name)

The corresponding interface record or subkey record is not described in the interface definition file.

S:
Invalidates the record and continues processing.

O:
Describe the interface record or subkey record in the relevant definition file.

KAVB1614-W


Invalid version (version) is specified. (PRODUCT_NAME="product-name":EVENT_ID="event-ID")

The specified version value is incorrect, or the context is described in reverse in the interface definition file.

Another possibility is that a definition with the same product name, version, and event ID already exists in the same file or another file.

S:
If the version value is incorrect, continues processing using the default value. If the context is in reverse, continues processing as is. If the definition is duplicated, uses the definition that is read first based on alphabetic order.

O:
Define the correct version for the relevant definition file.

KAVB1631-E


An event color scheme file was not found. (File: file-name)

The default file does not exist, or there is no access permission.

S:
Uses the default setting of the system and continues processing. If there is no file for each JP1 user or no access permission, the system does not output the file and reads the default file.

O:
Check the presence of the file and the access permission. If there is no access permission, grant it. If there is no file, install again. If the file still does not appear after installation, use the data collection tool to collect data, and then contact a system administrator.

KAVB1632-E


An I/O error occurred during the reading of an event color scheme file. (File: file-name)

An I/O error occurred during reading of a file. Retry was executed three times; all failed.

S:
If the error occurs during reading of the file for each JP1 user, the system reads the default file. If the error occurs during reading of the default file, the system uses the default setting of the system and continues processing.

O:
Determine whether the file system is normal. If it is normal, use the data collection tool to collect data, and then contact a system administrator.

KAVB1633-E


A memory shortage occurred during the reading of an event color scheme file. (File: file-name)

A memory shortage occurred during reading of a file.

S:
Suspends file reading and continues processing using the default setting of the system.

O:
Check the memory usage of the unit where the server is operating. If memory is insufficient, allocate sufficient memory, and then log in to the system again. If memory is sufficient, use the data collection tool to collect data, and then contact a system administrator.

KAVB1634-E


A system error occurred during the reading of an event color scheme file. (File: file-name)

A system error occurred.

S:
Suspends file reading and continues processing using the default setting of the system.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1635-E


An attempt to read the system profile has failed. The default value will be used. (cause = reason)

An attempt to read the system profile failed.

S:
Suspends reading of the system profile and uses the system default setting to continue processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1636-E


An invalid value is specified for data-name in the system profile. The default value will be used. (invalid value = invalid-value,default value = default-value)

An invalid value is set for data in the system profile.

S:
Sets the default value for the invalid data and continues processing.

O:
Carefully review the specified value, and then restart Event Service.

KAVB1637-E


An I/O error occurred during reading of the system profile. A retry was performed but the file could not be read. The default values will be used. (file: file-name)

An I/O error occurred during reading of the system profile.

S:
Suspends reading of the system profile and uses the system default setting to continue processing.

O:
Determine whether the file system is abnormal. If it is normal, use the data collection tool to collect data, and then contact a system administrator.

KAVB1638-E


An attempt to read the severe-event attribute-value definition file has failed. The default settings will be used. (cause = reason)

An attempt to read the severe event attribute definition file failed.

S:
Suspends reading of the severe event attribute definition file and uses the system default setting to continue processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1639-E


A setting in the severe-event attribute-value definition file is invalid. The default settings will be used. (cause = reason)

An invalid value is set for data in the severe event attribute value definition file.

S:
Sets the default values for the invalid data and continues processing.

O:
Reconfigure the data values, and then restart Event Service.

KAVB1640-E


An I/O error occurred during reading of the severe-event attribute-value definition file. The default settings will be used. (file: file-name)

An I/O error occurred during reading of the severe event attribute value definition file.

S:
Suspends reading of the severe event attribute value definition file and uses the system default setting to continue processing.

O:
Determine whether the file system is abnormal. If it is normal, use the data collection tool to collect data, and then contact a system administrator.

KAVB1647-E


An I/O error occurred during reading of the user filter definition file. A retry was performed, but the file could not be read. Startup will use the default values.

An I/O error occurred during reading of the user filter definition file.

S:
Suspends reading of the user filter definition file and uses the system default setting to continue processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1648-E


An I/O error occurred during reading of the severe-event filter definition file. A retry was performed, but the file could not be read. Startup will use the default values.

An I/O error occurred during reading of the severe event filter definition file.

S:
Suspends reading of the severe event filter definition file and uses the system default setting to continue processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1649-E


Binding failed for at least one IP address. (IP address of successful bind = IP-address, IP address of failed bind = IP-address)

Some IP addresses could not be bound.

S:
Uses the bound socket to continue processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1650-E


An attempt to read common definition information has failed. Startup will use the default values. (key = key-name, default value = default-value)

An attempt to read common definition information failed.

S:
Suspends reading of the common definition information and uses the default value to continue processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1651-E


An invalid value is specified for key-name common definition information has failed. Startup will use the default values. (invalid data = invalid-value)

An invalid value is specified for the key name of common definition information.

S:
Suspends reading of the common definition information and uses the default value for the key name to continue processing.

O:
Reconfigure the value for the key name, and then restart the event server.

KAVB1652-E


Failed to initialize the Event Console Service. The Event Console Service terminates abnormally. Details: detailed-information

An attempt to initialize Event Console Service failed.

S:
Terminates Event Console Service.

O:
Check the integrated trace log to determine if an Event Console Service error message (KAVB0001 to KAVB2000), KAVB8605-E, KAVB8606-E, or KAVB8607-E was output.
If a message is output, take the corrective action given for that message.
If the problem cannot be resolved, check the following OS log items to determine whether a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1653-E


An error occurred during communication processing of the event console service. A retry was performed, but recovery was not successful. Communication processing will now be initialized.

Communication processing will be initialized again.

S:
Re-initializes communication processing.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1654-E


An error occurred during re-initialization of communication processing of the event console service. The error prevents re-initialization from continuing.

Event Console Service ended abnormally.

S:
Terminates Event Console Service.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1655-E


An error occurred during a connection request from JP1/IM-View.

An error occurred while processing a connection request from JP1/IM - View.

S:
Suspends connecting to JP1/IM - View.

O:
Use the data collection tool to collect data, and then contact a system administrator.

KAVB1656-I


Reloading the manager because a reload request was received.

A reload request was accepted.

S:
Starts reloading the manager.

KAVB1657-I


A request request was received.

For request selected in the window, execution was requested to the connected server.

S:
Continues processing.

KAVB1658-I


The max. number of concurrent executions which can be processed by the server was exceeded.
Wait a while, perform request again.
(max. number = maximum-number)

For request selected in the window, execution was requested to the connected server, but the request was not executed because the maximum number of simultaneous executions by the connected server was exceeded.

S:
Continues processing.

O:
Wait awhile, and then retry the operation.

KAVB1660-E


The event base service cannot be connected to.
Event information could not be acquired.

The event could not be obtained because a connection could not be established to Event Base Service.

S:
Stops acquiring the event.

O:
Execute the jco_spmd_status command to make sure that Event Base Service is running on the manager host, and then retry the operation.

KAVB1661-E


The IM Database service cannot be connected to.
Event information could not be acquired.

The event could not be acquired because a connection could not be established to the IM database service.

S:
Stops acquiring the event.

O:
Execute the jco_spmd_status command to make sure that the IM database service is running on the manager host, and then retry the operation.

KAVB1662-E


The selected event no longer exists in the Integrated Monitoring Database.
Information about the selected event could not be acquired.

Information about the selected event could not be acquired because the selected event no longer exists in the integrated monitoring database.

S:
Stops acquiring information about the event.

KAVB1663-E


The event base service cannot be connected to.
The effects of the operation operation-name could not be applied to the Integrated Monitoring Database.

The effects of the operation indicated in the message could not be applied to the integrated monitoring database because a connection could not be established to Event Base Service.

S:
Suspends processing.

O:
Execute the jco_spmd_status command to make sure that Event Base Service is running on the manager host, and then retry the operation.

KAVB1664-E


The IM Database service cannot be connected to.
The effects of the operation operation-name could not be applied to the Integrated Monitoring Database.

The effects of the operation indicated in the message could not be applied to the integrated monitoring database because a connection could not be established to the IM database service.

S:
Suspends processing.

O:
Execute the jco_spmd_status command to make sure that the IM database service is running on the manager host, and then retry the operation.

KAVB1665-E


The selected event no longer exists in the Integrated Monitoring Database.
An event exists for which the effects of the operation operation-name could not be applied to the Integrated Monitoring Database.

The effects of the operation indicated in the message could not be applied to the integrated monitoring database because the selected event no longer exists in the integrated monitoring database.

S:
Suspends processing.

KAVB1668-E


The selected event no longer exists in the Integrated Monitoring Database.
The effects of the operation operation-name could not be applied to the Integrated Monitoring Database.

The effects of the operation indicated in the message could not be applied to the integrated monitoring database because the selected event no longer exists in the integrated monitoring database.

S:
Suspends processing.

KAVB1669-I


The severe event definition file has been read. Next, processing will be performed using the definition read from the acquired event. (Event acquired at the end:Arrival time = arrival-time-of-the-event-acquired-at-the-end, serial number in event DB = serial-number-in-event-database-of-the-event-acquired-at-the-end)

This message is output when a severe event definition file is read.

KAVB1670-W


An attempt to perform manager host identification processing has failed.
The response status cannot be changed from the Search Event page.

The response status cannot be changed because search host and manager host identification processing failed. The response status can only be changed using the search results from the event database of the manager host that has logged in.

S:
Continues processing without changing the response status from the Event Search page.

O:
Determine whether there is a communication problem with the search host, and then retry the operation.
If the system does not recover from the error after retrying the operation, use the data collection tool to collect data, and then contact a system administrator.

KAVB1671-W


An error occurred in acquiring an event from the integrated monitoring database.
Cannot recover the error after attempting the number of retries specified in the system profile.
No more events will be displayed from now on due to this error.

An error occurred during acquisition of an event from the integrated monitoring database.

S:
Stops event search processing.

O:
Make sure that the IM database service is running. If it is not running, start the IM database service, and then retry the operation.

KAVB1672-E


Memo entries could not be set because the function that sets the memo entries is disabled.

The edited memo entries could not be applied to the integrated monitoring database because the memo entry setting function is disabled.

S:
Stops processing.

O:
Enable the memo entry setting function, and then retry the operation.

KAVB1673-E


The operation-name operation could not be performed on the integrated monitoring database because that database is currently inactive.

The operation contents of the Event Console window could not be applied to the integrated monitoring database because the integrated monitoring database is inactive.

S:
Continues processing.

O:
Activate the integrated monitoring database or log in to the system again, and then retry the operation.

KAVB1674-E


The operation-name operation could not be performed on the integrated monitoring database because an error occurred in that database.

The operation contents of the Event Console window could not be applied to the integrated monitoring database because an error occurred during operation of the integrated monitoring database.

S:
Continues processing.

O:
  • Make sure that the IM database service is running. If it is not running, start the service, and then retry the operation.
  • Determine whether a memory shortage occurred. If so, restart JP1/IM - Manager, and then retry the operation.
  • Determine whether the manager host was in high load status. If so, wait awhile, and then retry the operation.
  • If the cause is other than the above or you cannot recover from the error after retrying the operation, contact a system administrator.

KAVB1675-E


The operation-name operation could not be performed on the integrated monitoring database because the event service could not connect to that database.

The operation contents of the Event Console window could not be applied to the integrated monitoring database because a connection could not be established to Event Service.

S:
Continues processing.

O:
  • Make sure that Event Service is running on the manager. If it is not running, start Event Service, and then retry the operation.
  • Determine whether a memory shortage occurred. If so, restart JP1/IM - Manager, and then retry the operation.
  • Determine whether the manager host was in high load status. If so, wait awhile, and then retry the operation.
  • If the cause is other than the above or you cannot recover from the error after retrying the operation, contact a system administrator.

KAVB1676-E


The operation-name operation could not be performed on the integrated monitoring database because an error occurred in the event database.

The operation contents of the Event Console window could not be applied to the integrated monitoring database because an error occurred during operation of the event database.

S:
Continues processing.

O:
  • Determine whether a memory shortage occurred. If so, restart JP1/IM - Manager, and then retry the operation.
  • Determine whether the manager host was in high load status. If so, wait awhile, and then retry the operation.
  • If the cause is other than the above or you cannot recover from the error after retrying the operation, contact a system administrator.

KAVB1677-E


Information about the selected events could not be acquired because the integrated monitoring database is currently inactive.

Information about the selected events could not be acquired because the integrated monitoring database is inactive.

S:
Stops processing.

O:
Activate the integrated monitoring database or log in to the system again, and then retry the operation.

KAVB1678-E


Information about the selected events could not be acquired because an error occurred in the integrated monitoring database.

Information about the selected events could not be acquired because an error occurred during operation of the integrated monitoring database.

S:
Stops processing.

O:
  • Make sure that the IM database service is running. If it is not running, start the service, and then retry the operation.
  • Determine whether a memory shortage occurred. If so, restart JP1/IM - Manager, and then retry the operation.
  • Determine whether the manager host was in high load status. If so, wait awhile, and then retry the operation.
  • If the cause is other than the above or you cannot recover from the error after retrying the operation, contact a system administrator.

KAVB1680-Q


The event search will be canceled. Is this OK?

Confirms that it is OK to cancel event search.

O:
Click the Yes button to cancel event search. Click the No button to continue event search.

KAVB1681-I


The event search was canceled.

Event search cancellation processing was completed normally.

KAVB1682-E


An attempt to cancel the event search has failed.

An attempt to cancel search processing failed even though event search was canceled.

S:
Stops cancellation processing.

O:
Check the following items:
  • Is Event Service running on the searched host?
  • Has a network error occurred?
  • Is sufficient memory allocated?
If there is no problem with the above items, use the data collection tool to collect data, and then contact a system administrator.

KAVB1683-W


processing is not possible during an event search.
Wait until the event search has ended.

processing cannot be performed because event search is in progress in JP1/IM - Manager.

S:
Displays the message box in the foreground.

O:
Cancel event search, or wait until event search ends.

KAVB1684-I


The event search has already ended.

Search processing had already ended even though event search was canceled.

S:
Terminates cancellation processing.

KAVB1685-W


The event acquired from the event service during the event search will be ignored because the event contains invalid information. (event database serial number = serial-number-in-event-database, reason code = reason-code)

The acquired event was ignored because invalid information was included in the event acquired from Event Service during event search.

S:
Ignores the event that contains invalid information and continues processing.

O:
Check the following items:
  • When the reason code is 3:
    The event arrival time is invalid. Make sure that the time is set correctly.
  • When the reason code is 4:
    The event registered time is invalid. Use the manager to determine whether the system time is set correctly.
If the above time is correct or the cause is other than the above, use the data collection tool to collect data, and then contact a system administrator.

KAVB1691-W


The filter setting from JP1/IM - View was discarded because filter that use the action type are specified in JP1/IM - Manager.

The setting from JP1/IM - View was invalidated because a filter using the action type is set in JP1/IM - Manager.

S:
Invalidates the setting from JP1/IM - View and continues processing.

O:
To set a filter for which the action type is specified in JP1/IM - Manager, use JP1/IM - View version 08-00 or later.

KAVB1701-E


An attempt to write data to the action profile (file-name) has failed. (detailed information = detailed-information)

An attempt to write data to the action profile failed.

S:
Stops writing data to the action profile and restores the previous status of the action profile.

O:
To update the action profile, open the Conditions for Updating List of Action Results window, and then close it.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\actprofile
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\actprofile
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/actprofile
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/actprofile
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1702-E


An attempt to write data to the settings file (file-name) for consolidated display of repeated events has failed. (detailed information = detailed-information)

An attempt to write data to the settings file for consolidated display of repeated events failed.

S:
Stops writing data to the settings file for consolidated display of repeated events and restores the previous status of the settings file for consolidated display of repeated events.

O:
In the Preferences window, reconfigure consolidated display of repeated events.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\correlation
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\correlation
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/correlation
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/correlation
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1703-E


An attempt to write data to the view filter definition file (file-name) has failed. (detailed information = detailed-information)

An attempt to write data to the view filter definition file failed.

S:
Stops writing data to the view filter definition file, restores the previous status of the view filter definition file, and continues processing.

O:
In the Settings for View Filter window, reconfigure the view filter.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\filter
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\filter
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/filter
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/filter
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1704-E


An attempt to write data to the event acquisition filter definition file (file-name) has failed. (detailed information = detailed-information)

An attempt to write data to the event acquisition filter definition file failed.

S:
Stops writing data to the event acquisition filter definition file and restores the previous status of the event acquisition filter definition file.
Continues processing without updating the settings in the manager.

O:
In the System Environment Settings window, reconfigure the event acquisition filter.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\filter
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\filter
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/filter
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/filter
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1705-E


An attempt to write data to the event acquisition filter list file (file-name) has failed. (detailed information = detailed-information)

An attempt to write data to the event acquisition filter list storage file failed.

S:
Stops writing data to the event acquisition filter list storage file and restores the previous status of the event acquisition filter list storage file.
Continues processing without updating the settings in the manager.

O:
In the System Environment Settings window, reconfigure the event acquisition filter.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\filter
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\filter
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/filter
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/filter
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1706-E


An attempt to write data to the event search filter definition file (file-name) has failed. (detailed information = detailed-information)

An attempt to write data to the event search filter definition file failed.

S:
Stops writing data to the event search filter definition file, restores the previous status of the event search filter definition file, and continues processing.

O:
In the Event Search Conditions window, reconfigure the event search conditions.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\filter
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\filter
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/filter
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/filter
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1707-E


An attempt to write data to the severe event(s) filter definition file (file-name) has failed. (detailed information = detailed-information)

An attempt to write data to the event acquisition filter definition file failed.

S:
Stops writing data to the severe event filter definition file and restores the previous status of the severe event filter definition file.
Continues processing without updating the settings in the manager.

O:
In the Severe Event Definitions window, reconfigure the severe event filter.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\filter
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\filter
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/filter
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/filter
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1708-E


An attempt to write data to the event receiver filter definition file (file-name) has failed. (detailed information = detailed-information)

An attempt to write data to the user filter definition file failed.

S:
Stops writing data to the user filter definition file and restores the previous status of the user filter definition file.
Continues processing without updating the settings in the manager.

O:
In the Settings for Event Receiver Filter window, reconfigure the user filter.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\filter
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\filter
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/filter
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/filter
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1709-E


An attempt to write data to the event-information mapping definition file (file-name) has failed. (detailed information = detailed-information)

An attempt to write data to the event information mapping definition file failed.

S:
Stops writing data to the event information mapping definition file and restores the previous status of the event information mapping definition file.
Continues processing without updating the settings in the manager.

O:
In the Event-Information Mapping Definitions window, reconfigure the event information mapping definitions.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\mapping
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\mapping
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/mapping
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/mapping
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1710-E


An attempt to write data to the system profile (file-name) has failed. (detailed information = detailed-information)

An attempt to write data to the system profile failed.

S:
Stops writing data to the system profile and restores the previous status of the system profile.
Continues processing without updating the settings in the manager.

O:
In the System Environment Settings window, reconfigure the system environment.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\profile
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\profile
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/profile
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/profile
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1711-E


An attempt to write data to the user profile (file-name) has failed. (detailed information = detailed-information)

An attempt to write data to the user profile failed.

S:
Stops writing data to the user profile and restores the previous status of the user profile.
Continues processing without updating the settings in the manager.

O:
In the Preferences window, reconfigure the user environment.
Also check the following items:
  • Is sufficient disk space allocated?
  • Is sufficient system physical memory and virtual memory allocated?
  • Does a file with the same name, not a folder (directory), exist in the paths below?
  • Is access permission set for any of the folders (directories) in the paths below?

In Windows:
Physical host:
Console_path\conf\console\profile
Console_path\conf\tmp
Logical host:
shared-folder\jp1cons\conf\console\profile
shared-folder\jp1cons\conf\tmp

In UNIX:
Physical host:
/etc/opt/jp1cons/conf/console/profile
/etc/opt/jp1cons/conf/tmp
Logical host:
shared-directory/jp1cons/conf/console/profile
shared-directory/jp1cons/conf/tmp
If the problem cannot be resolved, check the following OS log items to determine if a shortage occurred with OS resources such as file descriptors.
  • In Windows: Windows event log
  • In UNIX: syslog
If a resource shortage did not occur, use the data collection tool to collect data, and then contact a system administrator.

KAVB1821-E


Memory shortage occurred.

A memory shortage occurred.

S:
Suspends processing.

O:
Check memory usage of the machine where JP1/IM - Manager is running. If memory is insufficient, restart JP1/IM - Manager. If there is no memory shortage, use the data collection tool to collect data, and then contact a system administrator.

KAVB1831-E


An attempt to establish a connection to the IM database service has failed.

An attempt to connect to the IM database service failed.

S:
Suspends processing.

O:
Use the jimdbstatus command to determine whether the IM database service is running. If it is not running, start the service.
If the IM database service is running, use the data collection tool to collect data, and then contact a system administrator.

KAVB1832-E


An error occur while attempting to register an event into the integrated monitoring database. The system will retry registering the event. (detailed information = detailed-information)

An error occurred during registration of an event in the integrated monitoring database.

S:
Retries event registration processing.

O:
Use the jimdbstatus command to determine whether the IM database service is running. If it is not running, start the service.
If the IM database service is running, determine whether a 3F54 event that notifies recovery of event registration processing was issued or a KAVB1833-I message was output in the integrated trace log.
If the system does not recover from the error, collect data, and then contact a system administrator.

KAVB1833-I


An error occur while attempting to register an event into the integrated monitoring database. However, after several retries, the event was registered into the database. The event base service is restarting event acquisition.

The system recovered from an error that occurred while registering an event in the integrated monitoring database.

S:
Resumes registering the event in the integrated monitoring database.

KAVB1834-E


A system error occur while attempting to register an event into the integrated monitoring database.

A system error occurred during registration of an event in the integrated monitoring database.

S:
Suspends processing.

O:
Collect data, and then contact a system administrator.

KAVB1841-I


The events from deletion-target-start-date-and-time to deletion-target-end-date-and-time were deleted from the integrated monitoring database.

Events from the deletion target start date to the deletion target end date were deleted from the integrated monitoring database.

KAVB1842-W


Events not output for preservation have exceeded the deletion warning level (deletion-warning-level%).

The ratio of JP1 events that have not been output and saved for preservation in the integrated monitoring database exceeded the deletion warning notification level.

KAVB1843-Q


An event condition that has not been specified in the Event Condition list has been added. Would you like to delete this condition?

Confirms that it is OK to delete unspecified event conditions from the definition because event conditions that have not been specified in the Event conditions list have been added.

O:
Click the Yes button to delete events. Click the No button to cancel deleting events.

KAVB1844-E


An abnormal the IM database termination has been detected.

Abnormal stop of the IM database service was detected.

S:
Retries connecting to the IM database service.

O:
Restart the IM database service.

[Contents][Back][Next]


[Trademarks]

All Rights Reserved. Copyright (C) 2009, Hitachi, Ltd.