Job Management Partner 1/Integrated Management - Manager Overview and System Design Guide
Typically, communication is established between the viewer and manager when a user logs in to JP1/IM - Manager from JP1/IM - View, and is terminated when the user logs out. Communication is also terminated according to the timeout period set in JP1/IM (default 2,500 milliseconds) when communication processing between the viewer and manager takes too long or the manager goes down and fails to respond to requests. To change the communication timeout period, you must change the setting for the viewer (JP1/IM - View) and the manager (JP1/IM - Manager (JP1/IM - Central Console)). You do not need to do so for JP1/IM - Manager (JP1/IM - Central Scope).
The following table lists the ports used for communication between JP1/IM - View and JP1/IM - Manager.
Table 7-5 Ports used for communication between JP1/IM - View and JP1/IM - Manager
Service Port number Description jp1imevtcon 20115/tcp Used to connect to JP1/IM - Manager (event console service) from JP1/IM - View. jp1imcmda 20238/tcp Used to execute commands from JP1/IM - View. jp1imcss 20305/tcp Used to connect to JP1/IM - Manager (Central Scope service) from JP1/IM - View. jp1imcf 20702/tcp# Used to connect to JP1/IM - Manager (IM Configuration Management service) from JP1/IM - View.
- #
- Port used for communication between JP1/IM - View and JP1/IM - Manager when using IM Configuration Management.
If you use the Web-based JP1/IM - View, the following ports are used for communication between the viewer and manager.
Table 7-6 Ports used for communication between the viewer and manager when using the Web-based JP1/IM - View
Service Port number Description http 80/tcp# Used to connect to the Web server (to download console.html from JP1/IM - Manager). jp1imevtcon 20115/tcp Used to connect to JP1/IM - Manager (event console service) from the Web-based JP1/IM - View (through a Web browser). #: The port number may differ depending on how the Web server is set up.