Job Management Partner 1/Integrated Management - Manager Overview and System Design Guide

[Contents][Glossary][Index][Back][Next]


4.2.4 Event generation condition

A monitoring node can issue a JP1 event when its status changes.

As an event generation condition, you can specify the type of status change that will cause the node to issue a JP1 event. This JP1 event cannot be issued when the node status changes to Initial.

The issued JP1 event has event ID 00003FB0.

Details about this JP1 event are as follows. This information is taken from 3. JP1 Events in the manual Job Management Partner 1/Integrated Management - Manager Command and Definition File Reference.

Table 4-3 Details about event ID 00003FB0 (from the above manual)

Attribute type Item Attribute name Contents
Basic Source event server name SOURCESERVER The name of the event server that issued the JP1 event
Message MESSAGE KAVB7900-I Status of monitoring-node-name is changed status from status.
Extended Common
information
Event level SEVERITY Information
Product name PRODUCT_NAME /HITACHI/JP1/IM/SCOPE
Object type OBJECT_TYPE SERVICE
Object name OBJECT_NAME IM_CS
Occurrence OCCURRENCE STATUS_CHANGE
Program-
specific information
Monitoring node ID MON_NODE_ID The ID of the monitoring node
Monitoring node name MON_NODE_NAME The name of the monitoring node
Monitoring node status#1 MON_NODE_STATUS The StatusID of the monitoring node
Information about the JP1 event that triggered the status change#2 attribute-name The attribute value (basic attribute value prefixed with JCS_B_ or extended attribute value prefixed with JCS_E_)

#1: The monitoring node status (E.MON_NODE_STATUS) is stored as one of the following numeric values, which is called the node's StatusID.

For example, the JP1 event issued when the status of the monitoring node changes to Emergency has a monitoring node status (E.MON_NODE_STATUS) of 800.

#2: You cannot check this information from JP1/IM - View. Every item of information is stored as an attribute name combined with the attribute value. Therefore, when JP1 event 00003FB0 exceeds the maximum length of a JP1 event (10,000 bytes), only the portion within that limit is stored as information about the JP1 event that triggered the status change. Similarly, when the number of extended attributes exceeds 100, only the JP1 event information up to the 100th attribute is stored. Attributes are stored only if the attribute name is within 26 characters; if the attribute name exceeds 26 characters, the attribute is not saved.


Setting an automated action for a monitoring node

To execute an automated action when the status of a monitoring node changes:

Information about the JP1 event resulting in a node status change is included in JP1 event 00003FB0, as shown in Information about the JP1 event that triggered the status change in the above table. For example, the original event message (B.MESSAGE) can be used as the attribute name E.JCS_B_MESSAGE with the automated action.

[Contents][Back][Next]