An abnormality was detected during the monitoring of the public cloud environment.
An abnormality was detected during the CLI availability check.
- S:
-
Continues processing.
- O:
-
Contact a system administrator.
- Action:
-
- In the AWS environment:
-
See "[AWS] Configuring AWS" in the manual For Public Cloud Systems HA Monitor Cluster Software Guide, and revise the settings to correct errors.
If you cannot determine the cause of the AWS CLI failure, HA Monitor is unable to perform hot-standby switchover. In this case, ask AWS support for an investigation based on the execution log (/opt/hitachi/HAmon/spool/cloud/moncld_polling.log), and then take appropriate actions.
- In an Azure or OCI environment:
-
If this message was output when HA Monitor started, the settings for running the CLI in the public cloud are not specified, or the settings are invalid. Revise the settings to correct errors by referring to the following section in the For Public Cloud Systems HA Monitor Cluster Software Guide: "[Azure] Configuring Azure" or "[OCI] Configuring OCI".
If this message is output while HA Monitor is running, an attempt to run the CLI has failed. Check whether communication to the endpoint is possible. If you cannot determine the cause of the CLI failure, HA Monitor is unable to perform hot-standby switchover. In this case, ask Azure or OCI support for an investigation based on the CLI execution log (/opt/hitachi/HAmon/spool/cloud/moncld_polling.log), and then take appropriate actions.