Program:aa....aa, the patrol method is not corresponding to the definition. Signal:bb....bb Process ID:cc....cc.

Operation reports will not be monitored because the UAP indicated by the program alias name does not define the monitoring method in the same way as the hamon_patrolstart function for one of the following reasons:

  • A nonzero value was specified as the signum argument for the hamon_patrolstart function (which specifies monitoring of operation reports), but the patrol operand was not specified in the monitor-mode program environment definition.

  • 0 was specified as the signum argument for the hamon_patrolstart function (which specifies process monitoring), but the patrol operand was specified in the monitor-mode program environment definition.

aa....aa: Program alias name

bb....bb: signum value specified in the hamon_patrolstart function

cc....cc: Process ID of the UAP that invoked the hamon_patrolstart function

S:

Monitors the UAP process. Does not monitor UAP operation reports.

O:

Contact a system administrator.

Action:

If monitoring of UAP operation reports is necessary, specify tan appropriate signum value in the hamon_patrolstart function, and then restart the process. Alternatively, specify the patrol operand in the monitor-mode program environment definition, and then restart the UAP.