Hitachi

HA Monitor Cluster Software Messages


KAMN684-E

Abnormality of HAmonitor in the own host was detected. Own host cannot be system reset.

Error details:aa....aa

The local system cannot perform a reset, nor can it be reset from a remote system, because an error has been detected on the local HA Monitor, as indicated by the cause code.

aa....aa: Cause code

Cause code

Meaning

ATTACH

A daemon failed to start.

PIPE

A pipe system call error occurred.

FORK

A fork system call error occurred.

CONNECT

A communication error occurred.

NOEXIST

A daemon terminated abnormally.

S:

Continues processing.

O:

The action to take differs depending on whether the cause code is PIPE or something else.

If the cause code is PIPE, perform the following actions:

  • The reset path might not have been set by the HA Monitor environment setup command (monsetup). Check the setting of the reset path. If the path has not been set, force HA monitor to terminate normally, set the reset path with monsetup, and then restart HA Monitor.

    If the KAMN601-W message was output before this message was output and the issued system call is bind, the cause is one of the following:

    - The port number specified for the reset path port number in the reset path settings is the same as the port number being used by the monitoring path or is already being used by another program. Specify a number that is not being used. Review the reset path settings and configuration, and then execute the reset path status display command (monrp).

    - HA Monitor was started during execution of the command for setting the reset path (when the -resetpath option was specified for the monsetup command). Do not start HA Monitor during setup of the reset path. End the specification of settings for the reset path, and then execute the reset path status display command (monrp).

If the cause code is something other than PIPE, perform the following actions:

  • If message KAMN601-W is output before this message, eliminate the cause of the system call error as indicated by that message, and then execute the reset path status display command (monrp).