KAMN625-W

The definition of Reset Path was changed.

The reset path setting was changed. Possible causes are as follows:

  1. After the value specified for the address operand in the HA Monitor environment settings was changed, HA Monitor was restarted. This is not a problem.

  2. One of the following settings is incorrect. A reset during a hot-standby switchover might fail.

    - The value specified for the address operand in the HA Monitor environment settings is duplicated across multiple hosts.#

    - The system partition names and LPAR names specified by the environment settings command for the reset path of HA Monitor (monsetup) are duplicated across multiple hosts.#

    #: For duplicated hosts, if a different hot-standby switchover configuration shares a reset path, the hosts of that hot-standby switchover configuration are also included.

S:

Continues processing.

O:

For cause 1, no action is required.

For cause 2, perform the following procedure:

  1. Stop all instances of HA monitor in a hot-standby switchover configuration that includes hosts for which settings are incorrect.

  2. Correct the settings on all hosts for the instances of HA Monitor that were stopped in step 1, and then restart HA Monitor.

  3. Execute the monrp on all hosts, including hosts other than those for which HA Monitor was stopped in step 1, and then verify that the status of the reset path is normal.