Hitachi

HA Monitor Cluster Software Messages


KAMN512-E (E)

LAN monitor definition file corresponding to LAN interface:aa....aa cannot be used. Details:bb....bb

Either the LAN monitoring definition file corresponding to the specified LAN interface cannot be used, or the LAN interface specified in the LAN monitoring definition file cannot be used.

aa....aa: LAN interface name

bb....bb: Detail code

Detail code

Meaning

0x00000001

The name of the LAN interface to be monitored, as specified in the LAN monitoring definition file, exceeds 32 bytes.

0x00000002

The LAN to be monitored, as specified in the LAN monitoring definition file, does not exist in the system.

0x00000003

The LAN monitoring definition file cannot be read.

0x00000004

A directory was specified for the LAN monitoring definition file.

0x00000007

The IP address or IP label specified in the LAN monitoring definition file has not been specified in the /etc/hosts file.

0x00000008

The same IP address or IP label was specified in the LAN monitoring definition file more than once.

0x00000009

A LAN monitoring definition file statement is invalid.

0x0000000A

When monitoring hbonding, the number of IP addresses or IP labels specified in the LAN monitoring definition file is invalid. The invalid value depends on each specification of the lancheck_mode operand as follows.

If the operand is omitted or if packet is specified:

The following values are invalid:

  • 0 or between 2 to 1,024

If route is specified:

The following values are invalid:

  • 0 or between 1 to 1,024

When monitoring ethernet or bonding, the number of IP addresses or IP labels specified in the LAN monitoring definition file is either of the following for each specification of the lancheck_mode operand.

If the operand is omitted or if packet is specified:

The value is not between 2 and 1,024.

If route is specified:

The value is not between 1 and 1,024.

S:

Continues processing.

O:

Contact a system administrator.

Action:

Check the LAN monitoring definition file. Correct the definition, as needed, and then restart HA Monitor.