Hitachi

HA Monitor Cluster Software Messages


KAMN291-W

Disconnection of the volume group:bb....bb of the server:aa....aa was skipped.

Disconnection of the volume group of the server indicated by the server alias name was skipped. The system continues processing while maintaining the connection.

aa....aa: Server alias name

bb....bb: Volume group name

S:

Continues processing.

O:

Disconnect the device if necessary.

Action:

Eliminate the cause of the error for the system call indicated in the message KAMN234-E, which is output before this message. If the device name is a file system name, consult the switching log acquired in the /opt/hitachi/HAmon/spool/server-ID-name.fslog file to determine the cause of the error. If the device name is a volume group name, consult the connection log acquired in the /opt/hitachi/HAmon/spool/volume-group-name.vglog file to determine the cause of the error.