KAMN234-E

bb....bb of server:aa....aa cannot be disconnected.

A device on the server indicated by the server alias name cannot be disconnected. Processing continues with the device connected. If the replication software (DRBD) is being used, this message might be output depending on the timing for starting the standby server. In this case, there is no problem and no action is required.

aa....aa: Server alias name

bb....bb: Device name

S:

Continues processing.

O:

Disconnect the device, if necessary. It is possible that resources have been corrupted, particularly if a file system is being used; be sure to disconnect the device if a file system is being used.

Action:

Determine the cause of the error. If the device name is a file system name, check the switching log acquired in the /opt/hitachi/HAmon/spool/server-ID-name.fslog file. If the device name is a volume group name, check the connection log acquired in the /opt/hitachi/HAmon/spool/volume-group-name.vglog file.