Hitachi

HA Monitor Cluster Software Messages


KAMN176-E

It could not be connected with host:aa....aa specified as definition file:connection.

The host specified in the connection configuration file could not be connected to, despite connection processing reaching its limit. The possible causes are as follows:

  • The host is not running.

  • The connection configuration file contains an error.

  • The attempt to communicate failed because the monitoring path contained an error.

aa....aa: Host name

S:

Ignores the host that cannot be connected, and continues processing.

O:

If the host is running when this message is received, check the connection configuration file. If a TCP/IP LAN is being used for the monitoring path, check the contents of the HA Monitor environment settings, the /etc/hosts file, and the /etc/services file. If there is an error in a file, correct the error, and then connect to the HA Monitor using the HA Monitors manual connection command (monlink). If there is no error, there might be an error in communications with the host.

If you cannot connect despite executing the monlink command several times, eliminate any monitoring path errors, and then restart HA Monitor.