Hitachi

HA Monitor Cluster Software Messages


KAMN008-E (E+L)

Shared memory cannot be gotten.

Cause code:aa....aa Memory size:bb....bb

HA Monitor cannot start because a shared memory area cannot be allocated. For details about cause codes, see the documentation for the applicable OS.

aa....aa: Cause code (errno returned by the system call when an attempt was made to allocate shared memory, 1 to 3 digits)

bb....bb: Size of memory you attempted to allocate (bytes)

S:

Terminates processing.

O:

Check the amount of memory currently available in the system. If the amount of available system memory is less than the value shown by bb....bb, change the system value, and then restart HA Monitor. If the value is larger, report the amount of memory allocated and the cause code to a system administrator.

Action:

Eliminate the cause of the system call error as indicated by KAMN650-E, which is output before this message.