KFAA40214-E

An error occurred in a system call. (func = aa....aa, errno = bb....bb) (M)

A system call error occurred.

aa....aa:

Name of system call in which the error occurred

bb....bb:

Error number

S:

Terminates processing.

Action:

If the system call name (function) is malloc, the HADB server is not able to allocate sufficient process common memory. Use the following procedure to resolve a shortage of process common memory:

  1. Check for any unnecessary processes. If there are any unnecessary processes, shut them down.

  2. If there is not enough process common memory after performing step 1, restart the OS. Then, execute the adbstart command to start the HADB server.

  3. If there is not enough process common memory after performing step 2, change the kernel parameter setting to increase the amount of memory that processes can use. After restarting the OS, execute the adbstart command to start the HADB server.

If other error messages are also displayed, check those messages and eliminate the cause of the error. Then, re-execute the command.

For details about the corrective action to take, also see Command-related problems in the HADB Setup and Operation Guide.

If necessary, restore the database before re-executing the command. For details about how to restore the database, see the corrective action to take when a command terminates abnormally in the manual HADB Command Reference.