Nonstop Database, HiRDB Version 9 System Operation Guide
A warning message can be output when a resource utilization factor shown in Table 8-11 Resources whose utilization factors can be monitored reaches a specified value. Whether the warning messages are to be output is specified in system common definition operands. These operands can also be used to specify output trigger values for the warning messages. For example, a warning message can be output when a resource's utilization factor reaches 90%.
Table 8-11 Resources whose utilization factors can be monitored
Operand specified# | Monitored resource | Output warning message |
---|---|---|
pd_max_users_wrn_pnt | Maximum number of concurrent connections, as specified in the pd_max_users operand | KFPS05123-W |
pd_max_access_tables_wrn_pnt | Number of base table that can access as specified in the pd_max_access_tables operand | |
pd_max_rdarea_no_wrn_pnt | Maximum number of RDAREAs, as specified in the pd_max_rdarea_no operand | |
pd_max_file_no_wrn_pnt | Maximum number of HiRDB files comprising an RDAREA, as specified in the pd_max_file_no operand | |
pdwork_wrn_pnt | HiRDB file system areas for work table files, as specified in the pdwork operand | |
pd_max_list_users_wrn_pnt | Maximum number of users who can create lists, as specified in pd_max_list_users | |
pd_max_list_count_wrn_pnt | Maximum number of lists that can be created by a user, as specified in pd_max_list_count | |
pd_aud_file_wrn_pnt | Number of audit trail files that cannot be swapped | |
pd_rdarea_list_no_wrn_pnt | Number of lists created in a server | KFPH22023-W |
#: When pd_watch_resource = AUTO is specified, the warning message is output when a resource utilization factor shown in Table 8-11 Resources whose utilization factors can be monitored exceeds 80%. In this case, the operands shown in Table 8-11 Resources whose utilization factors can be monitored need not be specified. To change message output triggers (to values other than 80%), use these operands to specify the appropriate output trigger values.
All Rights Reserved. Copyright (C) 2011, 2015, Hitachi, Ltd.