OpenTP1 Version 7 Programming Reference COBOL Language
CBLDCMCF('TACTLE ') - Release a logical terminal from shutdown status
Format
PROCEDURE DIVISION specification
CALL 'CBLDCMCF' USING unique-name-1 unique-name-2 |
DATA DIVISION specification
01 unique-name-1. 02 data-name-A PIC X(8) VALUE 'TACTLE '. 02 data-name-B PIC X(5). 02 FILLER PIC X(3). 02 data-name-C PIC X(4) VALUE SPACE. 02 data-name-D1 PIC X(1) VALUE SPACE. 02 data-name-D2 PIC X(1). 02 data-name-D3 PIC X(26) VALUE SPACE. 02 data-name-E PIC 9(9) COMP. 02 data-name-F1 PIC X(8). 02 data-name-F2 PIC X(56) VALUE SPACE. 02 data-name-G PIC X(8) VALUE SPACE. 02 data-name-H PIC X(8) VALUE SPACE. 02 data-name-I PIC X(144) VALUE SPACE. 02 data-name-J PIC X(184) VALUE SPACE. 02 data-name-K1 PIC 9(9) COMP. 02 data-name-K2 PIC X(n). 01 unique-name-2. 02 data-name-L PIC 9(9) COMP VALUE ZERO. |
Description
CBLDCMCF('TACTLE ') releases a logical terminal from shutdown status.
Normal termination of CBLDCMCF('TACTLE ') indicates that the logical terminal shutdown release request was accepted successfully by the protocol product. However, this does not necessarily mean that the logical terminal has been released from the shutdown status.
If you intend to perform any operation related to the logical terminal after calling CBLDCMCF('TACTLE '), first use CBLDCMCF('TLSLE ') to check the logical terminal's status.
Data areas whose values are set in the UAP
data-name-A
Specify VALUE 'TACTLE' for the request code indicating release of a logical terminal from shutdown status.
data-name-C, data-name-D1
Specify a space.
data-name-D2
Specifies whether functionality that depends on the communication protocol is being used.
data-name-D3
Specify a space.
data-name-E
Specify the MCF communication process identifier of the MCF communication service that has the logical terminal to be processed. The permitted value range is from 0 to 239.
If you specify 0, the system searches for the MCF communication service to which the specified connection ID belongs. In a configuration where many MCF communication services are running or when you issue this function many times from a UAP, we recommend that you specify the MCF communication process identifier.
data-name-F1
Specify the name of the logical terminal that is to be released from shutdown status. Express the logical terminal name as a maximum of 8 bytes. If the specified name is shorter than 8 bytes, pad the name with trailing spaces.
data-name-F2, data-name-G, data-name-H, data-name-I, data-name-J
Specify a space.
data-name-K1
Specify the length of a protocol-specific area. You can specify a maximum of 1024 bytes.
If you do not use functionality that depends on the communication protocol, specify 0.
data-name-K2
Specify contents for the protocol-specific area.
The permitted value depends on the communication protocol being used. For details, see the applicable OpenTP1 Protocol manual.
data-name-L
Specify 0.
Data area to which a value is returned from OpenTP1
data-name-B
A status code of 5 digits is returned.
Status codes
Status code | Explanation |
---|---|
00000 | Normal termination. |
71001 | CBLDCMCF('TACTLE ') cannot be accepted because MCF is under start processing. |
71002 | CBLDCMCF('TACTLE ') cannot be accepted because MCF is under termination processing. |
71004 | A memory shortage occurred during CBLDCMCF('TACTLE ') processing. |
71005 | A communication error occurred. For the cause, see the message log file. |
71006 | An internal error occurred. For the cause, see the message log file. |
71008 | The specified logical terminal name has not been registered. |
71009 | CBLDCMCF('TACTLE ') is not supported by the applicable communication process. |
71010 | Although the request to release the logical terminal from shutdown status was issued to the MCF communication process, the request was not accepted. For the cause, see the message log file. |
71011 | CBLDCMCF('TACTLE ') cannot be accepted because the logical terminal has been deleted. |
72028 | The value specified for data-name-A is invalid. |
72052 | <If '0' or a space is specified for data-name-D2> A nonzero value is specified for data-name-K1. |
<If '1' is specified for data-name-D2> A value smaller than 0 or greater than 1024 is specified for data-name-K1. |
|
72053 | A nonzero value is specified for data-name-L. |
72058 | The value specified for data-name-C is not a space. |
72059 | The value specified for data-name-D1 or data-name-D3 is not a space. |
The value specified for data-name-D2 is not 1, 0, or a space. | |
72061 | A value smaller than 0 or greater than 239 is specified for data-name-E. |
72063 | data-name-F1 begins with a space. |
72065 | The value specified for data-name-F2 is not a space. |
72066 | The value specified for data-name-G is not a space. |
72068 | The value specified for data-name-H is not a space. |
72070 | The value specified for data-name-I is not a space. |
72072 | The value specified for data-name-J is not a space. |
72074 | The character string specified for data-name-F1 contains an invalid character. |
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.