OpenTP1 Version 7 Tester and UAP Trace User's Guide
mcfauaps -s { MCF-communication-process-ID |
application-startup-process-ID }
[-e "[backout] [trace] [swmsg] [errevt]
[execap] [holdlimit]"]
-a application-name [-k application-name-type]
|
Sets the specified application in test mode and starts testing.
Enter the mcfauaps command only after shutdown of connection and completion of all message send and receive.
Table 9-4 IDs to be specified when testing ERREVT (mcfauaps command)
| ERREVT to be tested | ID to be specified | |
|---|---|---|
| MCF communication process ID | Application startup process ID | |
| Invalid application name notification event (ERREVT1) | Y | -- |
| Message discard event that is issued by abnormal termination before the dc_mcf_receive function is issued (ERREVT2) | -- | Y |
| Message discard event generated by shutdown (ERREVT2) | Y# | Y# |
| UAP abnormal termination notification event that is issued by abnormal termination during MHP execution (ERREVT3) | -- | Y |
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.