OpenTP1 Version 7 Tester and UAP Trace User's Guide
(1) Syntax
utols [server-name [server-name] ...]
|
(2) Function
Outputs the status of the test UAP managed by the tester service to standard output. Nothing is output if no test UAP exists.
The utols command can only be used when the tester service is active.
(3) Command arguments
- server-name ~<identifier of 1-8 characters>
Specify the name of the user server for which test status is to be displayed.
When specification is omitted, the status of all the user servers being tested is displayed.
(4) Output format
- One of the following is displayed as the test mode information for the UAP (value specified in the test_mode operand of the user service definition):
- target
- test_mode=target specified at startup
- usable
- test_mode=usable specified at startup
- dmyspp
- test_mode=dmyspp specified at startup
- simmhp
- test_mode=simmhp specified at startup
- Test user ID of the user who started the UAP.
**** is displayed when the UAP test mode is usable.
- Server name (up to 8 characters)
- Service group name (up to 31 characters).
Nothing is displayed when no service groups are specified.
- Name (up to 8 characters) of the debugger interlocked to the UAP.
Nothing is displayed when the UAP is not interlocked to the debugger.
If the OpenTP1 system is immediately shut down or if the test UAP is forcibly terminated while active or inactive, information may be displayed for the inactive or terminated UAP. To display information correctly, restart the UAP for which information was displayed in error.
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.